Strona 1 - Installation Guide

613-000818 Rev. BAT-8500 SeriesLayer 2+ FastEthernet SwitchesAT-8516F/SCAT-8524MAT-8524POEAT-8550GBAT-8550SPInstallation Guide

Strona 2

Tables10

Strona 3 - Industry Canada

11PrefaceThis guide provides the hardware installation instructions for you managed, Layer 2+ AT-8500 Series Fast Ethernet switch. This preface contai

Strona 4 - Translated Safety Statements

Preface12Safety Symbols Used in this DocumentThis document uses the safety symbols defined in Table 1.Table 1. Safety SymbolsSymbol Meaning Descriptio

Strona 5 - Contents

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide13Where to Find Web-based GuidesThe installation and user guides for all Allied Teles

Strona 6

Preface14Contacting Allied Telesis This section provides Allied Telesis contact information for technical support as well as sales or corporate inform

Strona 7

15Chapter 1OverviewThe AT-8500 Series switches are managed, Layer 2+ Fast Ethernet switches. These switches are designed to simplify the task of creat

Strona 8

Chapter 1: Overview16Model ConfigurationsTable 2 lists the basic model configurations.Table 2. Model ConfigurationsModel ConfigurationAT-8516F/SC 16

Strona 9

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide17Model DescriptionsAT-8516F/SC The AT-8516F/SC switch has 16 100Base-FX fiber optic

Strona 10

Chapter 1: Overview18AT-8524M The AT-8524M switch has 24 10/100Base-TX twisted pair ports and two module expansion slots. The twisted pair ports featu

Strona 11

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide19AT-8524POE The AT-8524POE switch has 24 10/100Base-TX ports with Power over Etherne

Strona 12

Copyright © 2008 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied

Strona 13

Chapter 1: Overview20AT-8550GB The AT-8550GB switch has 48 10/100Base-TX twisted pair ports, capable of operating at either 10 or 100 Mbps, with RJ-45

Strona 14 - Contacting Allied Telesis

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide21AT-8550SP The AT-8550SP switch has 48 10/100Base-TX twisted pair ports with RJ-45 c

Strona 15 - Overview

Chapter 1: Overview22Port DescriptionsThis section provides information on the following port types found on the AT-8500 Series switches: “10/100Base

Strona 16 - Model Configurations

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide23NoteIn order for a switch port to successfully Auto-Negotiate its duplex mode with

Strona 17 - Model Descriptions

Chapter 1: Overview2410/100/1000Base-TTwisted PairPortsThis section applies to Port 49R and Port 50R on the AT-8550GB and AT-8550SP switches.Type of C

Strona 18 - Chapter 1: Overview

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide25For 10 Mbps, the port requires Category 3 or better 100 ohm shielded or unshielded

Strona 19 - AT-8524POE

Chapter 1: Overview26Type of CableThe fiber optic ports can use either 50/125 or 62.5/125 micron multimode fiber optic cable.NoteDo not use single-mod

Strona 20

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide27Power Over EthernetThe following discussion applies only to the AT-8524POE switch.

Strona 21 - RPS INPUT

Chapter 1: Overview28described in Table 3. .A port connected to a network node that is not a powered device (that is, a device that receives its power

Strona 22 - Duplex Mode

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide29GBIC and SFP SlotsThe AT-8550GB switch has two GBIC slots, and AT-8550SP switch has

Strona 23 - Port Pinouts

3Electrical Safety and Emissions StandardsThis product meets the following standards.RFI Emissions FCC Class A, EN55022 Class A, EN61000-3-2, EN61000-

Strona 24

Chapter 1: Overview30Module Expansion SlotsThe AT-8516F/SC, AT-8524M, and AT-8524POE switches have two expansion slots. Each slot can accommodate an e

Strona 25 - Fiber Optic Ports

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide31LEDsThis section provides information on the LEDs found on the AT-8500 Series switc

Strona 26 - Type of Cable

Chapter 1: Overview32Table 5 describes the LEDs for the 10/100/1000Base-TX twisted pair ports, Ports 49R and 50R, on the AT-8550GB and AT-8550SP switc

Strona 27 - Power Over Ethernet

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide33Table 6 describes the LEDs for the 10/100Base-TX twisted pair ports on the AT-8524P

Strona 28

Chapter 1: Overview34Fiber Optic PortLEDsThis section applies to the AT-8516F/SC switch. The fiber optic ports on an AT-8516F/SC switch have two LEDs,

Strona 29 - GBIC and SFP Slots

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide35are defined in Table 7.NoteThe AT-8516F/SC switch does not have an LED Mode Select

Strona 30 - Module Expansion Slots

Chapter 1: Overview36System LEDs The system LEDs on the front panel display general status information, as described in Table 9.Mode - SPD Solid Green

Strona 31 - LED Mode Select

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide37RS-232 Terminal PortYou can use the RS-232 terminal port to establish a local (out-

Strona 32

Chapter 1: Overview38Power Options and ConnectorsThis section provides information about the power options and features on the AT-8500 Series switches

Strona 33

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide39AC PowerConnectorThe switch has a single AC power supply socket on the back panel,

Strona 34 - Fiber Optic Port

4Translated Safety StatementsImportant: The  indicates that a translation of the safety statement is available in a PDF document titled “Translated S

Strona 35 - Expansion Slot

Chapter 1: Overview40A Few Basics about Ethernet SwitchingAn Ethernet switch interconnects network devices, such as workstations, printers, routers, a

Strona 36

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide41transmits data. If an end node can receive or transmit data, but not both simultane

Strona 37 - RS-232 Terminal Port

Chapter 1: Overview42How a switch signals an end node to stop transmitting data differs depending on the speed and duplex mode of the end node and swi

Strona 38 - Power Options and Connectors

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide43Network TopologiesThis section illustrates several of the network topologies you ca

Strona 39 - DC Power

Chapter 1: Overview44Figure 10. Collapsed Backbone TopologyMixed Topology You can always combine topologies as well as build a larger network by conne

Strona 40 - MAC Address

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide45Figure 11 illustrates a network of three AT-8524M Fast Ethernet switches. The works

Strona 41 - Back Pressure

Chapter 1: Overview46

Strona 42

47Chapter 2InstallationThis chapter provides the installation procedures for the switch and contains the following sections: “Reviewing Safety Precau

Strona 43 - Fast Ethernet Switch

Chapter 2: Installation48Reviewing Safety PrecautionsPlease review the following safety precautions before you begin to install the chassis or any of

Strona 44

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide49Warning: As a safety precaution, install a circuit breaker with a minimum value of

Strona 45

5ContentsPreface ...

Strona 46

Chapter 2: Installation50Warning: This unit might have more than one power source. To reduce the risk of electric shock, disconnect all power sources

Strona 47 - Installation

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide51Selecting a Site for the SwitchObserve the following requirements when choosing a s

Strona 48 - Reviewing Safety Precautions

Chapter 2: Installation52Planning the InstallationTable 10 contains the cabling specifications for the twisted pair ports. NoteThe twisted pair ports

Strona 49

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide53Table 11 contains the cabling specifications for the fiber optic ports on an AT-851

Strona 50 - Chapter 2: Installation

Chapter 2: Installation54Unpacking the SwitchTo unpack the switch, perform the following procedure:1. Remove all components from the shipping package.

Strona 51

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide55Installing the Switch in a RackThe switch is shipped with two brackets for mounting

Strona 52 - Planning the Installation

Chapter 2: Installation562. Using a flat-head screwdriver, remove the snap-on plastic feet from the bottom of the switch, as shown in Figure 13.Figure

Strona 53

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide57Caution: Air vents must not be blocked and must have free access to the room ambien

Strona 54 - Unpacking the Switch

Chapter 2: Installation58Installing an Optional Expansion or Stacking ModuleThis section describes how to install an optional expansion or stacking mo

Strona 55

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide594. Pull the faceplate straight out of the slot. 5. Keep the faceplate in a safe are

Strona 56

Contents6Selecting a Site for the Switch ...

Strona 57

Chapter 2: Installation60Installing an Optional GBICTo install an optional GBIC in an AT-8550GB switch, perform the following procedure:NoteA GBIC can

Strona 58

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide61ferrules of the optical connector.Figure 17. Optical Bore and Ferrule of GBIC Modul

Strona 59 - 10/100/1000BASE-T

Chapter 2: Installation62Installing an Optional SFP TransceiverTo install an optional SFP transceiver in an AT-8550SP switch, perform the following pr

Strona 60 - Installing an Optional GBIC

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide63debris picked up on the ferrules of the optical connectors. Use an alcohol swab or

Strona 61

Chapter 2: Installation64Cabling the SwitchTo connect the data cables to the switch ports and to apply power to the switch, perform the following proc

Strona 62

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide65instructions on how to configure a port trunk, refer to the AT-S62 Management Softw

Strona 63

Chapter 2: Installation662. Attach the fiber optic data cables to the fiber optic ports, as shown in Figure 21.Figure 21. Attaching a Fiber Optic Cabl

Strona 64 - Cabling the Switch

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide67remote end node. For example, you cannot connect a fiber optic port with a maximum

Strona 65 - Optic Ports

Chapter 2: Installation68Powering on an AC Powered SwitchTo power on an AC powered switch, perform the following procedure:NoteIf you are installing a

Strona 66

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide694. If you installed an optional redundant power supply unit, connect one end of the

Strona 67 - Expansion

7FiguresFigure 1. AT-8516F/SC Switch Front and Back Panels 9Figure 2. AT-8524M Switch Front and Back Panels 10Figure 3. AT-8524POE Switch Front and

Strona 68

Chapter 2: Installation70Wiring and Powering on an DC Powered UnitTo provide power for a DC powered switch, perform the following steps:1. Before you

Strona 69

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide71WarningDo not strip more than the recommended amount of wire. (See Figure 26.) Stri

Strona 70

Chapter 2: Installation727. Secure the tray supply cable near the rack framework using multiple cable ties to minimize the chance of the connections b

Strona 71 - 40-60VDC

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide73Starting a Local Management SessionThe procedure in this section explains how to st

Strona 72

Chapter 2: Installation74 Parity: None Stop bits: 1 Flow control: NoneNoteThe port settings are for a DEC VT100 or ANSI terminal, or an equivalent

Strona 73 -  Data bits: 8

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide75Warranty RegistrationWhen you have finished installing the switch, fill out the enc

Strona 74 -  Flow control: None

Chapter 2: Installation76

Strona 75 - Warranty Registration

77Chapter 3TroubleshootingThis chapter contains information on how to troubleshoot the switch in the event that a problem occurs.If after following th

Strona 76

Chapter 3: Troubleshooting78 Verify that you are using the appropriate category of twisted pair cable: Category 3 or better for 10 Mbps operation and

Strona 77 - Troubleshooting

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide79example, you cannot connect a fiber optic port with a maximum distance of 40 kilome

Strona 78

Figures8Figure 1. AT-8516F/SC Switch Front and Back Panels...

Strona 79 - Fault LED is On Continuously

Chapter 3: Troubleshooting80Check the FAULT LED. During normal operations, the LED remains off, except for periods when the management software is sav

Strona 80

81Appendix ATechnical SpecificationsPhysical SpecificationsAT-8516F/SC and AT-8524M 4.4 cm x 44.0 cm x 22.2 cmDimensions (1.75 in. x 17.3 in. x 8.75

Strona 81 - Technical Specifications

Appendix A: Technical Specifications82Power SpecificationsInput Voltage:All models except for the AT-8524POE:AC 100-240 VAC, 2A Max, 50/60 HzDC 36-60

Strona 82 - Power Specifications

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide83RJ-45 Twisted Pair Port PinoutsFigure 29 illustrates the pin layout for an RJ-45 co

Strona 83

Appendix A: Technical Specifications84Table 14 lists the RJ-45 pin signals for the two 10/100/1000-Base-T ports on the AT-8550GB switch when the ports

Strona 84

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide85AT-8516F/SC Fiber Optic Port SpecificationsStandard: 100Base-FXSpeed: 100 MbpsMaxim

Strona 85

Appendix A: Technical Specifications86RS-232 Terminal Port PinoutsTable 15 lists the pin signals on the RS-232 terminal port.Table 15. RS-232 Termin

Strona 86 - RS-232 Terminal Port Pinouts

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide87RPS Connector Port PinoutsFigure 30 illustrates the pin layout to the 16-pin molex

Strona 87 - RPS Connector Port Pinouts

Appendix A: Technical Specifications88Figure 31 illustrates the pin layout to the RPS connector on the AT-8524POE switch.Figure 31. AT-8524POE RPS Co

Strona 88 - 12 3.3V RS

AT-8500 Series Layer 2+ Fast Ethernet Switches Installation Guide8913 3.3V RS+14 3.3V15 3.3VTable 17. Pin Definitions for the RPS Connector on the A

Strona 89

9Table 1. Safety Symbols .........

Strona 90 - Dual SC Type Connector

Appendix A: Technical Specifications90Dual SC Type ConnectorA dual SC type connector, as shown in Figure 32, is used with the AT-8516F/SC switch.Figur