Strona 1 - Installation Guide

AT-FS201AT-FS201ST/FS1, FS2, FS3 AT-FS202AT-FS202SC/FS1, FS2, FS3 AT-FS203Fast Ethernet SwitchesInstallation GuidePN 613-10761-00 Rev B

Strona 2

Welcome to Allied TelesynxFor Sales or Corporate InformationTell Us What You ThinkIf you have any comments or suggestions on how we might improve this

Strona 3 - Safety Warnings

1Chapter 1DescriptionThe AT-FS201, AT-FS202, and AT-FS203 Series of Fast Ethernet Switches are designed to interconnect LAN devices and subnetworks ov

Strona 4

Description2Figure 2 AT-FS202 Front PanelFigure 3 AT-FS203 Front PanelFigure 4 Rear Panel of the AT-FS203 Switch10Base-T/100Base-TXAUTO NEG10Base-T

Strona 5 - Table of Contents

AT-FS200 Series Installation Guide3Figure 5 AT-FS201ST Series Front PanelCLASS 1LASER PRODUCTDO NOT STAREINTO BEAM100Base-FX10Base-T/100Base-TXFS201S

Strona 6

Description4Figure 6 AT-FS202SC Series Front PanelsAT-FS202SC/FS1AT-FS202SC/FS2AT-FS202SC/FS3100Base-FX10Base-T/100Base-TXAUTO NEGTXRXCOLLNKPWR100FDM

Strona 7 - Welcome to Allied Telesyn

AT-FS200 Series Installation Guide5Figure 7 illustrates the rear panel of the AT-FS201SC and AT-FS202ST Series Switches.Figure 7 Rear Panel of the AT

Strona 8 - Contacting Allied Telesyn

Description6Key FeaturesThe switches have the following key features:❑LEDs for unit and port status❑MDI/MDI-X switch ❑External AC/DC power adapters (N

Strona 9 - FTP Server

AT-FS200 Series Installation Guide7Switch PerformanceThe switches perform at:❑148,800 pps for 100 Mbps and 14,880 pps for 10 Mbps for full wire speed

Strona 10 - Tell Us What You Think

Description8Status LEDsTable 2 defines the switch LEDs.External AC/DC Power AdapterThe power adapter supplies 12V DC to the switch. Allied Telesyn sup

Strona 11 - Description

AT-FS200 Series Installation Guide9MDI/MDI-X SwitchThe MDI/MDI-X (Media Dependent Interface/Media Dependent Interface with Crossover) switch, located

Strona 12 - 12 V D C

Copyright  2000 Allied Telesyn International, Corp.960 Stewart Drive, Suite B, Sunnyvale CA 94086 USAAll rights reserved. No part of this publication

Strona 13 - AT-FS201ST Series Front Panel

Description10Functional DescriptionThe AT-FS200 series of switches function as unmanaged dual-port switches.Frame ProcessingThe switches support store

Strona 14 - Figure 6

AT-FS200 Series Installation Guide11Network TopologiesFigure 10 shows a network configuration where an AT-FS203 Switch is used to interconnect two sma

Strona 16 - Key Features

13Chapter 2Installing the SwitchThis chapter explains how to install the switch. The switch can be installed either as a standalone unit, such as on a

Strona 17

Installing the Switch14Planning the InstallationBe sure to observe the following guidelines when planning the installation of your Ethernet switch.❑Th

Strona 18 - Status LEDs

AT-FS200 Series Installation Guide15❑Refer to Table 4 for the cabling specifications for the fiber optic port operating in full-duplex mode.NoteRefer

Strona 19 - PORT 2PORT 1

Installing the Switch16❑Refer to Table 5 for the cabling specifications for the fiber optic port operating in half-duplex mode.1. The total distance

Strona 20 - Frame Processing

AT-FS200 Series Installation Guide17Installing the SwitchTo install the switch, perform the following procedures:1. Remove all equipment from the pack

Strona 21 - Network Topologies

Installing the Switch18When setting the DIP switches, consider the following:❑The default setting of 1518 bytes for the maximum packet size is the upp

Strona 22

AT-FS200 Series Installation Guide19Figure 12 AT-FS201SC and AT-FS202ST DIP Switches4. If you are installing the switch as a standalone unit, plug th

Strona 23 - Installing the Switch

iiiSafety WarningsStandards: This product meets the following standardsRFI EmissionEN55022 Class A  1Warning: In a domestic environment this product

Strona 24 - Planning the Installation

Installing the Switch20Figure 13 MDI/MDI-X SwitchWarranty RegistrationWhen you finish the installation, register your product by completing the enclo

Strona 25

AT-FS200 Series Installation Guide21Connectivity Testing1. Connect each port to a node or workstation. Then connect the power cord.2. Verify that the

Strona 26 - Selecting a Site

Installing the Switch223. Problem 3:The MDI/MDI-X slide switch for TX is on the wrong setting.❑Solution 3:— Verify that you are using a known good cab

Strona 27

23Table 8 lists the technical specifications for the Fast Ethernet Switches.Table 8 Technical Specifications Physical SpecificationsDimensions (L x W

Strona 28

Technical Specifications24TransmitterOutput Power 62.5/125 mM -16.8 dBm100/140 mM50/125 mM-20.3 dBm85/125 mMTable 9 Fiber Optic TransmitterModelFiber

Strona 29

AT-FS200 Series Installation Guide25Table 10 Fiber Optic ReceiverModelFiber TypeFiber Optic Diameter (microns)Optical Frequency (nm)Receive Power (dB

Strona 30 - Troubleshooting

Technical Specifications26Pinout AssignmentsFigure 14 shows the pin assignments of the switch’s 10/100Base-TX RJ-45 connector.Figure 14 RJ-45 Pin Ass

Strona 31

27Appendix BElectrical Safety and Installation RequirementsImportant: This appendix contains multiple-language translations for the safety statements

Strona 32 - Technical Support and Service

Electrical Safety and Installation Requirements28Standards: This product meets the following standards. 1 RFI EmissionEN55022 Class A 2 Warning: In

Strona 33 - Technical Specifications

AT-FS200 Series Installation Guide29Normen: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen. 1 HochfrequenzstörungEN55022 Klasse A

Strona 34

Safety WarningsivImportant: L'annexe B contient les instructions de sécurité relatives à l'installation de cet équipement. Lorsque vous voye

Strona 35

Electrical Safety and Installation Requirements30SIKKERHED 10 FARE UNDER UVEJRFARE: UNDLAD at arbejde på udstyr eller KABLER i perioder med LYNAKTIVI

Strona 36 - Pinout Assignments

AT-FS200 Series Installation Guide31Normes: ce produit est conforme aux normes de suivantes. 1 Emission d'interférences radioélectriquesEN55022

Strona 37 - Requirements

Electrical Safety and Installation Requirements32 12Tähtipisteeseen (hub) syötettävän virran pitää tulla ainoastaan sovittimesta.EUROPE - EUKäytä TÜV

Strona 38

AT-FS200 Series Installation Guide33Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer. 1 RFI strålingEN55022 Klasse A 2 A

Strona 39

Electrical Safety and Installation Requirements34EUROPE - EUUse um adaptador de corrente alternada com saída DC de 12V e 500mA em conformidade com as

Strona 40

AT-FS200 Series Installation Guide35Standarder: Denna produkt uppfyller följande standarder. 1 RadiostörningEN55022 Klass A 2 Varning: Denna produk

Strona 42

37Appendix CTechnical Support Fax OrderName __________________________________________________________________Company ________________________________

Strona 44

39Appendix DAT-FS201, AT-FS202 and AT-FS203 Series Installation Guide FeedbackPlease tell us what additional information you would like to see discuss

Strona 45

vTable of ContentsSafety Warnings ... iiiTable of Contents ..

Strona 47 - Technical Support Fax Order

Table of ContentsviIs the Link LED Lit? ... 21Technical Support and Serv

Strona 48

viiThis guide contains instructions on how to install the AT-FS201, AT-FS202, and AT-FS203 Series of Fast Ethernet Switches.Where to Find Web-based Gu

Strona 49 - Installation Guide Feedback

Welcome to Allied TelesynviiiContacting Allied TelesynThere are several ways to contact Allied Telesyn technical support: online, telephone, fax, and

Strona 50

AT-FS200 Series Installation GuideixReturning ProductsProducts for return or repair must first be assigned a Return Materials Authorization (RMA) numb

Komentarze do niniejszej Instrukcji

Brak uwag