Allied-telesis AT-S94 CLI (AT-8000S Series) Instrukcja Użytkownika Strona 82

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 402
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 81
Page 81
Allied Telesis
AT-8000S-S94-3.0 Command Line Interface Users Guide
Example
The following example configures the device to accept SNTP traffic from the server on 192.1.1.1.
show clock
The show clock User EXEC mode command displays the time and date from the system clock.
Syntax
show clock [detail]
Parameters
detailShows timezone and summertime configuration.
Default Configuration
This command has no default configuration.
Command Mode
User EXEC mode
User Guidelines
The symbol that precedes the show clock display indicates the following:
Example
The following example displays the time and date from the system clock.
Console(config)#
sntp server
192.1.1.1
Symbol Description
* Time is not authoritative.
(blank) Time is authoritative.
. Time is authoritative, but SNTP is not synchronized.
Console> show clock
15:29:03 PDT(UTC-7) Jun 17 2002
Time source is SNTP
Console>
show clock detail
15:29:03 PDT(UTC-7) Jun 17 2002
Time source is SNTP
Przeglądanie stron 81
1 2 ... 77 78 79 80 81 82 83 84 85 86 87 ... 401 402

Komentarze do niniejszej Instrukcji

Brak uwag