Parameter Description
Index
Syslog server settings index (1-4).
Server IP The IP address of the Syslog server.
Severity This drop-down menu allows you to select the level of messages that will be sent.The options are Warning,
Informational
, and All.
Facility Some of the operating system daemons and processes have been assigned Facility values. Processes and
daemons that have not been explicitly assigned a Facility may use any of the "local use" facilities or they may use
the "user-level" Facility.Those Facilities that have been designated are shown in the following:
Bold font
denotes the facility values that the Switch currently implements.
Numerical Code Facility
0 kernel messages
1 user-level messages
2 mail system
3 system daemons
4 security/authorization messages
5 messages generated internally by syslog line printer subsystem
7 network news subsystem
8 UUCP subsystem
9 clock daemon
10 security/authorization messages
11 FTP daemon
12 NTP subsystem
13 log audit
14 log alert
15 clock daemon
16 local use 0 (local0)
17 local use 1 (local1)
18 local use 2 (local2)
19 local use 3 (local3)
20 local use 4 (local4)
21 local use 5 (local5)
22 local use 6 (local6)
23
l
ocal use 7 (l
ocal7)
UDP Port (514 or 6000-65535)
Type the UDP port number used for sending Syslog messages.The default is 514.
Status Choose Enabled or Disabled to activate or deactivate
.
T
o set the System Log Ser
v
er configuration, click
A
pply
.
T
o delete an entr
y from the
Curr
ent System Log Serv
er
windo
w
,
click the corresponding
8
under the Delete heading of the entry to delete.To return to the Current System Log Servers window, click the Show All System Log Servers link.
73
Allied Telesyn AT-9724TS High-Density Layer 3 Stackable Gigabit Ethernet Switch
Przeglądanie stron 73
1 2 ... 69 70 71 72 73 74 75 76 77 78 79 ... 196 197

Komentarze do niniejszej Instrukcji

Brak uwag