Overview
46
OFF, do the following:
Verify that the end node connected to the port is powered ON and is
operating properly.
Check that the twisted pair cable is securely connected to the port on
the AT-MC605 Ethernet Extender and to the port on the end node.
Make sure that the twisted pair cable does not exceed 100 meters
(328 feet).
Verify that you are using the appropriate category of twisted pair cable:
Category 3 or better for 10 Mbps operation, Category 5 and Category
5E for 100 Mbps operation.
Make sure that the operating parameters of the port on the
AT-MC605 Ethernet Extender are compatible with the end node to
which the port is connected.