613-001017 Rev AConverteon™ FamilyManagement SoftwareAT-S73 and AT-S99User’s GuideCONVERTEON™ Family Media Converter ProductsAT-S73 Version 3.0.0 Mana

Strona 2

Figures10Figure 51. Menu View...

Strona 3 - Contents

Chapter 4: Configuring the AT-CV5M02 Management Card100Table 9 lists the event messages.Table 9. Event Log MessagesMessage ChassisClassi-ficationDefin

Strona 4

AT-S73 and AT-S99 Management Software User’s Guide101CV1203 RPS Failure on Remote Line Card nAT-CV1203AT-CV5000Report The media converter line card in

Strona 5

Chapter 4: Configuring the AT-CV5M02 Management Card1024. To clear all the messages from the log, select Clear Event Log from the Event Log Menu.Fan T

Strona 6

AT-S73 and AT-S99 Management Software User’s Guide103Web Browser To view the event log from the web browser windows:1. Select Administrator from the m

Strona 7

Chapter 4: Configuring the AT-CV5M02 Management Card104Viewing the Activity MonitorThe activity monitor displays the event messages in real-time. For

Strona 8

AT-S73 and AT-S99 Management Software User’s Guide105Configuring the Syslog ClientFor background information, refer to “Syslog Client” on page 23.Menu

Strona 9

Chapter 4: Configuring the AT-CV5M02 Management Card1064. Select the Syslog IP Address field and enter the IP address of the syslog server on your net

Strona 10

AT-S73 and AT-S99 Management Software User’s Guide107Configuring the 10/100Base-TX PortThe procedures in this section explain how to set the speed and

Strona 11

Chapter 4: Configuring the AT-CV5M02 Management Card108The columns in the Module Configuration Menu are described in Table 10.3. Select Port A (100Bas

Strona 12

AT-S73 and AT-S99 Management Software User’s Guide109Figure 36. Port Configuration Menu for the 10/100Base-TX Port on the Management CardThe parameter

Strona 13

AT-S73 and AT-S99 Management Software User’s Guide11Figure 111. SNMPv3 Message Notification Process ...

Strona 14

Chapter 4: Configuring the AT-CV5M02 Management Card1105. To save your changes in the master configuration file, go to the Main Menu and select Config

Strona 15

AT-S73 and AT-S99 Management Software User’s Guide1113. Click the Port Configuration tab, shown in Figure 38.Figure 38. 10/100Base-TX Port on the Mana

Strona 16

Chapter 4: Configuring the AT-CV5M02 Management Card112Restoring the Default Setting on the 10/100Base-TX PortThese procedures are used to restore the

Strona 17 - Contacting Allied Telesis

AT-S73 and AT-S99 Management Software User’s Guide113Restoring the Default Values on the AT-CV5M02 Management CardIn this section are the procedures f

Strona 18 - Software Updates

Chapter 4: Configuring the AT-CV5M02 Management Card1144. Enter Y for Yes to restore the parameters on the management card to their default values or

Strona 19 - AT-CV5M02 Management Card

AT-S73 and AT-S99 Management Software User’s Guide115Configuring the Temperature ThresholdThe management card has a temperature threshold parameter to

Strona 20 - The Converteon Product Line

Chapter 4: Configuring the AT-CV5M02 Management Card1164. In the Temperature Threshold pop-up window, click the Maximum Temperature Threshold field an

Strona 21

AT-S73 and AT-S99 Management Software User’s Guide117Activating a Standby AT-CV5M02 Management CardThe procedures in this section activate the standby

Strona 22 - 10/100Base-TX Port

Chapter 4: Configuring the AT-CV5M02 Management Card1184. To resume managing the chassis, wait twenty to thirty seconds for the standby card to transi

Strona 23 - Syslog Client

AT-S73 and AT-S99 Management Software User’s Guide119Setting the Baud Rate of the Console PortThe RS-232 Console port on the front faceplate of the ma

Strona 25 - Management Access

Chapter 4: Configuring the AT-CV5M02 Management Card1204. Select Data rate (baud rate) to display the Terminal Data Rate Menu shown in Figure 44.Figur

Strona 26 - Redundant Management Cards

AT-S73 and AT-S99 Management Software User’s Guide121Displaying the Operational Status of the ChassisIn this section are procedures for displaying ope

Strona 27

Chapter 4: Configuring the AT-CV5M02 Management Card122Figure 46. Chassis Diagnostics MenuThe information in the Chassis Diagnostics Menu is defined i

Strona 28 - Access to Your Network

AT-S73 and AT-S99 Management Software User’s Guide123Web Browser To view the operational information from the web browser windows:1. Select Administra

Strona 29 - Configuration Files

Chapter 4: Configuring the AT-CV5M02 Management Card124Figure 47. Chassis Diagnostics Tab

Strona 30 - AT-CM Line

AT-S73 and AT-S99 Management Software User’s Guide125Pinging Network DevicesThe procedure in this section is used to test for live connections between

Strona 31 - Remote Peer

Chapter 4: Configuring the AT-CV5M02 Management Card126Displaying Management Card InformationTo view general information about the AT-CV5M02 Managemen

Strona 32 - Redundant

127Chapter 5Configuring AT-CM and AT-CV Media Converter Line CardsThis chapter has the following sections: “Displaying the Status of the Line Cards”

Strona 33

Chapter 5: Configuring AT-CM and AT-CV Media Converter Line Cards128Displaying the Status of the Line CardsMenus To view the states of the ports on th

Strona 34 - Converteon Chassis

AT-S73 and AT-S99 Management Software User’s Guide129OperMode This column displays different information depending on the type of card. For the AT-CM

Strona 35 - Line Cards

13Table 1. Converteon Chassis ...

Strona 36

Chapter 5: Configuring AT-CM and AT-CV Media Converter Line Cards130IPC (Continued) C This is the total number of responses the management card is wai

Strona 37

AT-S73 and AT-S99 Management Software User’s Guide131FIBER PORT or COPPER PORTST This column displays the states of the ports. The possible states are

Strona 38 - 2. Four T1/E1 ports

Chapter 5: Configuring AT-CM and AT-CV Media Converter Line Cards132OAM (Continued) A This displays the operational state of the OAM client on Port A,

Strona 39

AT-S73 and AT-S99 Management Software User’s Guide133Web Browser To view the states of the ports on the line cards from the web browser windows, click

Strona 40 -  Smart MissingLink

Chapter 5: Configuring AT-CM and AT-CV Media Converter Line Cards134Figure 50. Menu ViewTable 14. Module Status and Configuration WindowColumn Descrip

Strona 41

AT-S73 and AT-S99 Management Software User’s Guide135Link (A) This column displays the states of Port A on the AT-CM and AT-CV Line Cards. This is a f

Strona 42 - Operating Modes

Chapter 5: Configuring AT-CM and AT-CV Media Converter Line Cards136Displaying the Parameter Settings on AT-CM Line CardsMenus To view the current par

Strona 43 - MissingLink

AT-S73 and AT-S99 Management Software User’s Guide137This window is for viewing purposes only. The parameters for the fiber optic port and the twisted

Strona 44

Chapter 5: Configuring AT-CM and AT-CV Media Converter Line Cards138This window is for viewing purposes only. The parameters for the fiber optic port

Strona 45

AT-S73 and AT-S99 Management Software User’s Guide139Configuring the Port Parameters on AT-CM Line CardsNoteThe port settings on AT-CV Line Cards are

Strona 47

Chapter 5: Configuring AT-CM and AT-CV Media Converter Line Cards1403. Select the port you want to configure. You can configure only one port at a tim

Strona 48

AT-S73 and AT-S99 Management Software User’s Guide1414. Select Port Configurations. The Port Configuration Menu for the selected port is displayed. Th

Strona 49 - Remote line cards

Chapter 5: Configuring AT-CM and AT-CV Media Converter Line Cards142Auto negotiateManual negotiateFullHalfHundred Base <100Base-TX>Ten Base <

Strona 50

AT-S73 and AT-S99 Management Software User’s Guide1436. To save your changes in the master configuration file, return to the Module Configuration Menu

Strona 51 - OAM Loopback

Chapter 5: Configuring AT-CM and AT-CV Media Converter Line Cards1444. Click the Port Configuration tab to display the current settings of the port. T

Strona 52

AT-S73 and AT-S99 Management Software User’s Guide145Setting the Operating ModeFor background information, refer to “Operating Modes” on page 42.Cauti

Strona 53

Chapter 5: Configuring AT-CM and AT-CV Media Converter Line Cards1464. Select the new operating mode for the line card from the menu. You can select o

Strona 54

AT-S73 and AT-S99 Management Software User’s Guide147Web Browser To set the operating modes of the AT-CM and AT-CV Line Cards from the web browser win

Strona 55 - Requests

Chapter 5: Configuring AT-CM and AT-CV Media Converter Line Cards148normal operations because the cards in that series do not have management software

Strona 56 - OAM Client

AT-S73 and AT-S99 Management Software User’s Guide149Assigning Names to AT-CM Line CardsMenus To assign names to the AT-CM Line Cards from the menus:1

Strona 57 - Starting a Management Session

15PrefaceThis is the management guide for the Converteon™ product line of media converter line cards and management card. In this guide you’ll learn a

Strona 58 - AT-CV501

Chapter 5: Configuring AT-CM and AT-CV Media Converter Line Cards150Configuring the Maximum Frame Size on AT-CM2KOS Line CardsThe AT-CM Line Cards can

Strona 59

AT-S73 and AT-S99 Management Software User’s Guide151Setting the Auto-copy FeatureThese procedures set the auto-copy feature on the chassis slots that

Strona 60 - System name: ->

Chapter 5: Configuring AT-CM and AT-CV Media Converter Line Cards1525. Select the desired setting for the auto-copy feature for the line card’s slot.

Strona 61

AT-S73 and AT-S99 Management Software User’s Guide153Restoring the Default SettingsThe procedures in this section are used to restore the default sett

Strona 62

Chapter 5: Configuring AT-CM and AT-CV Media Converter Line Cards1544. To view the default settings of the line card prior to activating them, select

Strona 63 - Figure 12. Chassis View

AT-S73 and AT-S99 Management Software User’s Guide1557. To save your changes in the master configuration file, wait for the line card to finish initia

Strona 64

Chapter 5: Configuring AT-CM and AT-CV Media Converter Line Cards156This tab displays the line card’s default settings. 5. To return the parameter set

Strona 65

AT-S73 and AT-S99 Management Software User’s Guide157Restoring the Last Saved ConfigurationThese procedures restore AT-CM Line Cards to their last sav

Strona 66

Chapter 5: Configuring AT-CM and AT-CV Media Converter Line Cards158Web Browser To restore the last saved configuration to an AT-CM Line Card from the

Strona 67 - Switch Over Management Cards

AT-S73 and AT-S99 Management Software User’s Guide159This tab displays the last saved configuration settings for this card. The settings are obtained

Strona 68

Preface16Where to Find Web-based GuidesThe installation and user guides for all of the Allied Telesis products are available for viewing in portable d

Strona 69 - Passwords

Chapter 5: Configuring AT-CM and AT-CV Media Converter Line Cards160Displaying Port StatisticsMenus To display traffic statistics for the ports on the

Strona 70

AT-S73 and AT-S99 Management Software User’s Guide161Web Browser To display the traffic statistics for the ports on the AT-CM Line Cards from the web

Strona 71 - Setting the Date

Chapter 5: Configuring AT-CM and AT-CV Media Converter Line Cards162Resetting Media Converter Line CardsThe procedures in this section are used to res

Strona 72 - Saving Your

AT-S73 and AT-S99 Management Software User’s Guide163Web Browser To reset all of the media converter line cards in the chassis from the web browser wi

Strona 73

Chapter 5: Configuring AT-CM and AT-CV Media Converter Line Cards164Displaying the Version Numbers of the Management SoftwareThe procedures in this se

Strona 74

AT-S73 and AT-S99 Management Software User’s Guide1653. From the Diagnostics Menu, select Line Card Image Version. An example of the Line Card Module

Strona 75

Chapter 5: Configuring AT-CM and AT-CV Media Converter Line Cards166Web Browser To view the version numbers of the management software and bootloader

Strona 76

AT-S73 and AT-S99 Management Software User’s Guide167Displaying the MAC Addresses and Serial NumbersThis section has procedures that explain how to di

Strona 77

Chapter 5: Configuring AT-CM and AT-CV Media Converter Line Cards168This window is for viewing purposes only. The columns in the window are described

Strona 78

AT-S73 and AT-S99 Management Software User’s Guide169Figure 72. Linecard Information Window

Strona 79 - Management Card

AT-S73 and AT-S99 Management Software User’s Guide17Contacting Allied TelesisThis section provides Allied Telesis contact information for technical su

Strona 80

Chapter 5: Configuring AT-CM and AT-CV Media Converter Line Cards170Displaying SFP Module InformationThe procedures in this section are for viewing th

Strona 81

AT-S73 and AT-S99 Management Software User’s Guide171Figure 73. SFP Information Window (1/2)Figure 74. SFP Information Window (2/2)SFP InformationSlot

Strona 82

Chapter 5: Configuring AT-CM and AT-CV Media Converter Line Cards172Web Browser To view SFP information from the web browser windows:1. Select Adminis

Strona 83

173Chapter 6Configuring AT-CM Line Cards with Remote Peer ManagementThis chapter has the following sections: “Configuring Remote AT-CM Line Cards fro

Strona 84

Chapter 6: Configuring AT-CM Line Cards with Remote Peer Management174Configuring Remote AT-CM Line Cards from the MenusTo configure remote AT-CM Line

Strona 85 - Assigning a Name

AT-S73 and AT-S99 Management Software User’s Guide175ST This column displays the states of the remote peer management connections between the local an

Strona 86

Chapter 6: Configuring AT-CM Line Cards with Remote Peer Management176IPC (Continued) For AT-CM Line Cards this column displays the following informat

Strona 87

AT-S73 and AT-S99 Management Software User’s Guide177FIBER PORT or COPPER PORTST This column displays the states of the twisted pair ports on the remo

Strona 88

Chapter 6: Configuring AT-CM Line Cards with Remote Peer Management178NoteRemote peer management requires that the local and remote line cards be in t

Strona 89

AT-S73 and AT-S99 Management Software User’s Guide1792. To configure a remote line card, select the card in the menu. This displays the Remote Module

Strona 90

Preface18Go to www.alliedtelesis.com/warranty for the terms and conditions of the warranty and for warranty registration.ManagementSoftware UpdatesNew

Strona 91

Chapter 6: Configuring AT-CM Line Cards with Remote Peer Management180Displaying theCurrentConfigurationTo view the current settings of a remote card:

Strona 92

AT-S73 and AT-S99 Management Software User’s Guide181Restoring theLast SavedConfigurationThis procedure restores a remote line card to the last saved

Strona 93

Chapter 6: Configuring AT-CM Line Cards with Remote Peer Management182Configuring Remote AT-CM Line Cards from the Web Browser WindowsTo configure rem

Strona 94

AT-S73 and AT-S99 Management Software User’s Guide1832. To configure a remote line card, click the model name of its local line card counterpart to di

Strona 95

Chapter 6: Configuring AT-CM Line Cards with Remote Peer Management184NoteYou cannot disable the ports or change the operating modes or the OAM settin

Strona 96 - Resetting the Management Card

AT-S73 and AT-S99 Management Software User’s Guide185Restoring theDefaultParameterSettingsTo restore a remote line card to its default parameter setti

Strona 97

Chapter 6: Configuring AT-CM Line Cards with Remote Peer Management186Saving theParameterSettingsYour changes to the parameter settings on remote AT-C

Strona 98 - Viewing the Event Log

AT-S73 and AT-S99 Management Software User’s Guide187Displaying the Version Numbers of Remote AT-CM Line CardsThese procedures are used to view the ve

Strona 99

Chapter 6: Configuring AT-CM Line Cards with Remote Peer Management188The columns in the window are described in Table 22.Web Browser To view the vers

Strona 100

AT-S73 and AT-S99 Management Software User’s Guide189Figure 81. Remote Linecard Image Information TabThe information in this window is for viewing pur

Strona 101

19Chapter 1AT-CV5M02 Management CardThe sections in this chapter are: “The Converteon Product Line” on page 20 “AT-CV5M01 and AT-CV5M02 Management C

Strona 102

Chapter 6: Configuring AT-CM Line Cards with Remote Peer Management190

Strona 103

191Chapter 7Configuring the T1/E1 Ports on the AT-CM70S Media Converter Line CardThis chapter contains the following sections: “Selecting the Managem

Strona 104 - Viewing the Activity Monitor

Chapter 7: Configuring the T1/E1 Ports on the AT-CM70S Media Converter Line Card192Selecting the Management Method for the T1/E1 PortsThe parameter se

Strona 105 - Configuring the Syslog Client

AT-S73 and AT-S99 Management Software User’s Guide193that had a management card whenever you wanted to configure the T1/E1 ports.Figure 82. UART Setti

Strona 106

Chapter 7: Configuring the T1/E1 Ports on the AT-CM70S Media Converter Line Card194How to set the UART setting on the AT-CM70S Line Card is explained

Strona 107

AT-S73 and AT-S99 Management Software User’s Guide195Figure 84. UART Configuration Menu5. From the UART Configuration Menu, select one of the followin

Strona 108

Chapter 7: Configuring the T1/E1 Ports on the AT-CM70S Media Converter Line Card196Configuring the T1/E1 Ports from the AT-CV5M02 Management CardTo co

Strona 109

AT-S73 and AT-S99 Management Software User’s Guide1976. After you’ve designated the carrier type, configure the individual ports. Each channel in the

Strona 110

Chapter 7: Configuring the T1/E1 Ports on the AT-CM70S Media Converter Line Card1987. Adjust the settings as needed. Refer to Table 24 for the possibl

Strona 111

AT-S73 and AT-S99 Management Software User’s Guide199Configuring the T1/E1 Ports from the Console Port on the Line CardThis procedure explains how to

Strona 112

Copyright © 2008 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied

Strona 113

Chapter 1: AT-CV5M02 Management Card20The Converteon Product LineThe Converteon product line consists of modular fiber optic media converters that con

Strona 114

Chapter 7: Configuring the T1/E1 Ports on the AT-CM70S Media Converter Line Card200Figure 88. Local Console Menu on the AT-CM70S Line CardThe first se

Strona 115 - Converteon

AT-S73 and AT-S99 Management Software User’s Guide201b. At the confirmation prompt, type Y and press Return to implement the change or N and Return to

Strona 116

Chapter 7: Configuring the T1/E1 Ports on the AT-CM70S Media Converter Line Card202

Strona 117

203Chapter 8Configuring the Operations, Administration, and Maintenance ClientThe sections in this chapter are: “Configuring an OAM Client” on page 2

Strona 118

Chapter 8: Configuring the Operations, Administration, and Maintenance Client204Configuring an OAM ClientYou should set the operating modes of the AT-

Strona 119 - Data Rate (baud rate)

AT-S73 and AT-S99 Management Software User’s Guide2055. From the OAM Configuration Menu, select OAM Configuration to display the OAM Configuration sub

Strona 120

Chapter 8: Configuring the Operations, Administration, and Maintenance Client206Mode This parameter specifies the mode of the OAM client on the line c

Strona 121

AT-S73 and AT-S99 Management Software User’s Guide2076. To save your changes in the master configuration file, return to the Module Configuration Menu

Strona 122

Chapter 8: Configuring the Operations, Administration, and Maintenance Client208Web Browser To configure the OAM clients on the AT-CM Media Converter

Strona 123

AT-S73 and AT-S99 Management Software User’s Guide209Performing an OAM Loopback TestFor background information, refer to “OAM Loopback Tests” on page

Strona 124

AT-S73 and AT-S99 Management Software User’s Guide21AT-CV5M01 and AT-CV5M02 Management CardsThe AT-CV5M02 Management Card and its predecessor, the AT-

Strona 125 - Pinging Network Devices

Chapter 8: Configuring the Operations, Administration, and Maintenance Client2106. From the OAM Loopback Test Menu, select Enable Remote Loopback.Caut

Strona 126

AT-S73 and AT-S99 Management Software User’s Guide2118. To view test statistics, select Show Loopback Test Statistics. The Show Loopback Test Statisti

Strona 127 - Converter Line Cards

Chapter 8: Configuring the Operations, Administration, and Maintenance Client212Web Browser To run the loopback test from the web browser windows:Caut

Strona 128

AT-S73 and AT-S99 Management Software User’s Guide2136. To start the test, click Edit in the OAM Loopback Test field to display a pop-up window and se

Strona 129

Chapter 8: Configuring the Operations, Administration, and Maintenance Client214Displaying OAM Information for Local OAM ClientsThe procedures in this

Strona 130

AT-S73 and AT-S99 Management Software User’s Guide215Figure 96. Show Local OAM Information WindowThis window is for viewing purposes only. The items i

Strona 131

Chapter 8: Configuring the Operations, Administration, and Maintenance Client216Line Card Operation Mode(Continued) OAM Visible Mode – In this mode t

Strona 132

AT-S73 and AT-S99 Management Software User’s Guide217Parser StateIndicates the state of the parser function in the OAM peer as reflected in the latest

Strona 133

Chapter 8: Configuring the Operations, Administration, and Maintenance Client218Remote StableIndicates whether or not the remote OAM client is satisfi

Strona 134

AT-S73 and AT-S99 Management Software User’s Guide219Config RevisionIndicates the current revision of the Information TLV. The value of this field sta

Strona 135

Chapter 1: AT-CV5M02 Management Card22AT-S99 Management SoftwareThe AT-CV5M02 Management Card uses the AT-S99 Management Software. This program comes

Strona 136

Chapter 8: Configuring the Operations, Administration, and Maintenance Client220Web Browser To display status information for local OAM clients from t

Strona 137

AT-S73 and AT-S99 Management Software User’s Guide221Displaying OAM Information for Remote OAM ClientsThe procedures in this section are used to view

Strona 138

Chapter 8: Configuring the Operations, Administration, and Maintenance Client222This window is for viewing purposes only. Refer to Table 26 on page 21

Strona 139

AT-S73 and AT-S99 Management Software User’s Guide223Displaying OAM StatisticsNoteThese procedures require that the local and remote AT-CM Line Cards

Strona 140 - Port Management Menu

Chapter 8: Configuring the Operations, Administration, and Maintenance Client224Refer to the IEEE 802.3ah standard for definitions of the different ty

Strona 141

AT-S73 and AT-S99 Management Software User’s Guide225Viewing MIB Variables with OAM Variable RequestsThese procedures are used to send OAM variable re

Strona 142

Chapter 8: Configuring the Operations, Administration, and Maintenance Client2266. Enter the branch number of the MIB package or object to be returned

Strona 143

AT-S73 and AT-S99 Management Software User’s Guide2275. Click Edit to display the OAM Variable Request pop-up window.6. Select the Branch Number field

Strona 144

Chapter 8: Configuring the Operations, Administration, and Maintenance Client228

Strona 145 - Setting the Operating Mode

229Chapter 9Configuring AT-CM Line Cards for Dying GaspThe sections in this chapter are: “Configuring the AT-CM Line Cards” on page 230 “Testing the

Strona 146

AT-S73 and AT-S99 Management Software User’s Guide23IP Address ConfigurationTo support the functions listed in “10/100Base-TX Port” the management car

Strona 147

Chapter 9: Configuring AT-CM Line Cards for Dying Gasp230Configuring the AT-CM Line CardsThis procedure explains how to configure the settings of the

Strona 148

AT-S73 and AT-S99 Management Software User’s Guide231Figure 105. Line Card Module Software Image Version - Hardware Version Numbers5. In the same wind

Strona 149

Chapter 9: Configuring AT-CM Line Cards for Dying Gasp232Figure 106. Line Card Module Software Image Version - AT-S73 Version Numbers6. Return to the

Strona 150 - Max Frame Size: 1632

AT-S73 and AT-S99 Management Software User’s Guide233NoteIf the line card is already set to the OAM visible mode, go to step 11. Otherwise, continue t

Strona 151 - Setting the Auto-copy Feature

Chapter 9: Configuring AT-CM Line Cards for Dying Gasp23419. If the Mode parameter is set to Passive. highlight Mode and press Return to toggle the pa

Strona 152

AT-S73 and AT-S99 Management Software User’s Guide235Testing the FeatureTo test the feature:1. Verify that the AT-CV1203 and AT-CV5000 Chassis are pow

Strona 153

Chapter 9: Configuring AT-CM Line Cards for Dying Gasp236If the remote AT-CV1203 Chassis has two power supplies and the AT-CV5M02 Management Card, the

Strona 154

237Chapter 10Configuring SNMPv3This chapter provides a description of the AT-S99 implementation of the SNMPv3 protocol. In addition, the chapter conta

Strona 155

Chapter 10: Configuring SNMPv3238SNMPv3 OverviewThe SNMPv3 protocol builds on the existing SNMPv1 and SNMPv2c protocol implementation. In SNMPv3, User

Strona 156

AT-S73 and AT-S99 Management Software User’s Guide239SNMPv3AuthenticationProtocolsThe SNMPv3 protocol supports two authentication protocols—HMAC-MD5-9

Strona 157

Chapter 1: AT-CV5M02 Management Card24Network Time Protocol ClientThe management card has a Network Time Protocol (NTP) client for setting its date an

Strona 158

Chapter 10: Configuring SNMPv3240Figure 108. MIB TreeThe management software supports the MIB tree, starting with the Internet MIBs, as defined by 1.3

Strona 159

AT-S73 and AT-S99 Management Software User’s Guide241address and which portion represents the node address. In a similar way, the subtree mask further

Strona 160 - Displaying Port Statistics

Chapter 10: Configuring SNMPv3242SNMPv3 Tables The SNMPv3 configuration is neatly divided into configuring SNMPv3 user information and configuring the

Strona 161

AT-S73 and AT-S99 Management Software User’s Guide243After you configure an SNMPv3 user, you need to configure SNMPv3 message notification. This confi

Strona 162

Chapter 10: Configuring SNMPv3244For a more detailed description of the SNMPv3 Tables, see the following subsections: “SNMPv3 User Table” on page 244

Strona 163

AT-S73 and AT-S99 Management Software User’s Guide245group members to view the specified portion of the OID MIB table. The Write View allows group mem

Strona 164

Chapter 10: Configuring SNMPv3246SNMPv3ConfigurationExampleYou may want to have two classes of SNMPv3 users—Managers and Operators. In this scenario,

Strona 165

AT-S73 and AT-S99 Management Software User’s Guide247Configuring SNMPv3 EntitiesThe following sections describe how to configure SNMPv3 entities using

Strona 166

Chapter 10: Configuring SNMPv3248Configuring the SNMPv3 User TableThis section describes the parameters for SNMPv3 User Table entries. The parameters

Strona 167

AT-S73 and AT-S99 Management Software User’s Guide249Figure 112. SNMPv3 User Table TabThe parameters for SNMPv3 User Table entries are defined in Tabl

Strona 168

AT-S73 and AT-S99 Management Software User’s Guide25Management AccessThere are four ways to manage the Converteon product: Local management Remote T

Strona 169

Chapter 10: Configuring SNMPv3250Authentication Protocol (continued)N-NoneThis value represents no authentication protocol. When messages are received

Strona 170

AT-S73 and AT-S99 Management Software User’s Guide251Configuring the SNMPv3 View TableThis section describes the parameters for SNMPv3 View Table entr

Strona 171

Chapter 10: Configuring SNMPv3252Figure 114. SNMPv3 View Table TabA knowledge of the OID table is required to create view entities. You can be very sp

Strona 172

AT-S73 and AT-S99 Management Software User’s Guide253Subtree Mask A subtree mask in hexadecimal format. This is an optional parameter used to further

Strona 173 - Remote Peer Management

Chapter 10: Configuring SNMPv3254Configuring the SNMPv3 Access TableThis section describes the parameters for SNMPv3 Access Table entries. The SNMPv3

Strona 174

AT-S73 and AT-S99 Management Software User’s Guide255To manage the SNMPv3 View Table from the web browser windows: :Click the Configuration button in

Strona 175

Chapter 10: Configuring SNMPv3256Security Model The possible values are:Select one of the following SNMP protocols as the Security Model for this Grou

Strona 176

AT-S73 and AT-S99 Management Software User’s Guide257Read View Name The value that you configured with the View Name parameter in the SNMPv3 View Tabl

Strona 177

Chapter 10: Configuring SNMPv3258Configuring the SNMPv3 Group TableThis section contains a description of the SNMPv3 Group Table and how to create, de

Strona 178

AT-S73 and AT-S99 Management Software User’s Guide259Figure 118. SNMPv3 Group Table TabThe parameters for SNMPv3 Group Table entries are defined in Ta

Strona 179 - Line Card

Chapter 1: AT-CV5M02 Management Card26Redundant Management CardsYou can install two AT-CV5M02 Management Cards in the AT-CV5000 Chassis. The second ca

Strona 180

Chapter 10: Configuring SNMPv3260Group Name a Group Name that you configured in the SNMPv3 Access Table. Refer to “Configuring the SNMPv3 Access Table

Strona 181

AT-S73 and AT-S99 Management Software User’s Guide261Configuring the SNMPv3 Notify TableThe SNMPv3 Notify Table is used to create names for sending tr

Strona 182

Chapter 10: Configuring SNMPv3262Figure 120. SNMPv3 Notify Table TabThe parameters for SNMPv3 Notify Table entries are defined in Table 32.Table 32. S

Strona 183

AT-S73 and AT-S99 Management Software User’s Guide263Storage Type (Continued) N-NonVolatileThis selection allows the management card to save the entry

Strona 184 - Remote Ports

Chapter 10: Configuring SNMPv3264Configuring the SNMPv3 Target Address TableThe SNMPv3 Target Address Table is used to designate the IP addresses of h

Strona 185

AT-S73 and AT-S99 Management Software User’s Guide265To access the Configure SNMPv3 Target Address Table from the web browser windows: :Click the Con

Strona 186 - Settings

Chapter 10: Configuring SNMPv3266Retries The number of times the switch retrIes, or resends, an Inform message. When an Inform message is generated, a

Strona 187

AT-S73 and AT-S99 Management Software User’s Guide267Configuring the SNMPv3 Target Parameters TableThis section describes the parameters for entries i

Strona 188

Chapter 10: Configuring SNMPv3268To access the SNMPv3 Target Parameters Table from the menus: From the Main Menu, select Configuration -> System C

Strona 189

AT-S73 and AT-S99 Management Software User’s Guide269Security Model [1-v1, 2-v2c, 3-v3]The Security Model for this Security Name or User Name. The pos

Strona 190

AT-S73 and AT-S99 Management Software User’s Guide27 All of your local and remote management sessions have to be conducted through the active managem

Strona 191 - Chapter 7

Chapter 10: Configuring SNMPv3270In an SNMPv3 Target Parameters Table entry, the Security Name parameter is linked to the User Name parameter on the S

Strona 192

271Chapter 11Uploading and Downloading FilesThe procedures in this chapter explain how to update the management software on the AT-CV5M02 Management C

Strona 193 - AT-CV5000

Chapter 11: Uploading and Downloading Files272OverviewAllied Telesis may periodically release new versions of the management software for the Converte

Strona 194 - UART Configurations

AT-S73 and AT-S99 Management Software User’s Guide273Configuring the TFTP ClientThe procedure in this section explains how to configure the TFTP clien

Strona 195 - UART Back Plane Mode

Chapter 11: Uploading and Downloading Files274Management Card Image File Name - This field is for the image filename of the AT-S99 Management Software

Strona 196

AT-S73 and AT-S99 Management Software User’s Guide275Downloading New Management Software Using TFTPThe procedure in this section explains how to use T

Strona 197

Chapter 11: Uploading and Downloading Files276CautionUpdating the AT-S73 Management Software on the AT-CM Line Cards interrupts the cards' networ

Strona 198

AT-S73 and AT-S99 Management Software User’s Guide277slot number of the line card you want to upgrade. You can specify only one slot number.Single Loc

Strona 199

Chapter 11: Uploading and Downloading Files278After you’ve selected a download and provided the necessary information, the management card begins to d

Strona 200

AT-S73 and AT-S99 Management Software User’s Guide279Downloading New Management Software Using XMODEMThe procedure in this section explains how to use

Strona 201

Chapter 1: AT-CV5M02 Management Card28Access to Your NetworkThe management card must be able to access your network if it will be performing any of th

Strona 202

Chapter 11: Uploading and Downloading Files280Figure 128. Image Download via TFTP Menu3. Select one of the following menu options:Management Card Imag

Strona 203 - Configuring the Operations

AT-S73 and AT-S99 Management Software User’s Guide281Uploading the Master Configuration File from a Management CardYou can upload the master configura

Strona 204 - Configuring an OAM Client

Chapter 11: Uploading and Downloading Files282Ready to upload Configuration file through TFTP.Warning: During Upload Configuration Management activity

Strona 205

AT-S73 and AT-S99 Management Software User’s Guide283NoteIf you want to update the master configuration file before uploading it to the TFTP server, c

Strona 206

Chapter 11: Uploading and Downloading Files284Downloading the Master Configuration File to a Management CardThese procedures are used to download a ma

Strona 207

AT-S73 and AT-S99 Management Software User’s Guide285Do TFTP download now? (Yes or No):6. Type Y to start the download. This prompt is displayed:Downl

Strona 208

Chapter 11: Uploading and Downloading Files286During this process, which takes about two minutes to complete, the management card will be unresponsive

Strona 209

287Appendix ADefault Settings for the Management Software ProgramsThe following table lists the factory default settings for the AT-S99 Management Sof

Strona 210 - OAM is not in active mode

Appendix A: Default Settings for the Management Software Programs288This table lists the factory default settings for the AT-S73 Management Software o

Strona 211

AT-S73 and AT-S99 Management Software User’s Guide289Maximum OAMPDU Size 1518 octetsUnidirectional Support YesLoopback Support YesEvent Support NoVari

Strona 212

AT-S73 and AT-S99 Management Software User’s Guide29Configuration FilesThe management card and the media converter line cards store their parameter se

Strona 213

Appendix A: Default Settings for the Management Software Programs290

Strona 214

291Appendix BSNMPv3 Configuration ExamplesThis appendix provides two examples of SNMPv3 configurations using the SNMPv3 Table menus. In addition, a wo

Strona 215

Appendix B: SNMPv3 Configuration Examples292Configure SNMPv3 View Table Menu View Name: internetView Subtree OID: .1.3.6.1.2.1.6Subtree Mask: ffView T

Strona 216

AT-S73 and AT-S99 Management Software User’s Guide293Configure SNMPv3 Target Address Table Target Address Name: host408Ip Address: 198.35.11.1UDP Port

Strona 217

Appendix B: SNMPv3 Configuration Examples294Storage Type: NonVolatileConfigure SNMPv3 Access TableGroup Name: OperatorsSecurity Model: SNMPv3Security

Strona 218

AT-S73 and AT-S99 Management Software User’s Guide295Write View NameNotify View NameStorage TypeSNMPv3 Group Table MenuSecurity NameSecurity ModelGrou

Strona 219

Appendix B: SNMPv3 Configuration Examples296

Strona 220

297Appendix CPacket Rate Limiting on the AT-CM2K0S Line CardBecause of the component design on the AT-CM2K0S Line Card, the actual performance of pack

Strona 221

Appendix C: Packet Rate Limiting on the AT-CM2K0S Line Card298Table 37. Rate Limits EquivalentsSpecified Rate Limit (Kbps)Average Rate Limit Result (K

Strona 222

AT-S73 and AT-S99 Management Software User’s Guide299628 and 629 629630 Same631 and 632 632633 through 634 Same635 and 636 636637 Same638 and 639 6396

Strona 224

Chapter 1: AT-CV5M02 Management Card30sends the change to the designated card over the backplane of the chassis.2. The line card implements the change

Strona 225

Appendix C: Packet Rate Limiting on the AT-CM2K0S Line Card300673 673674 and 675 675676 and 677 677678 678679 and 680 680681 681682 and 683 683684 and

Strona 226

AT-S73 and AT-S99 Management Software User’s Guide301722 and 723 723724 and 725 725726 and 727 727728 728729 and 730 730731 and 732 732733 and 734 734

Strona 227

Appendix C: Packet Rate Limiting on the AT-CM2K0S Line Card302775 and 776 776777 and 778 778779 and 780 780781 and 782 782783 and 784 784785 through 7

Strona 228

AT-S73 and AT-S99 Management Software User’s Guide303838 to 840 840841 and 842 842843 through 845 845846 and 847 847851 and 852 852853 through 855 855

Strona 229 - Dying Gasp

Appendix C: Packet Rate Limiting on the AT-CM2K0S Line Card304916 through 918 918919 through 921 921922 through 924 924925 through 927 927928 through

Strona 230

AT-S73 and AT-S99 Management Software User’s Guide3051007 through 1009 10091010 through 1013 10131014 through 1016 10161017 through 1020 10201021 thro

Strona 231

Appendix C: Packet Rate Limiting on the AT-CM2K0S Line Card3061117 through 1120 11201121 through 1124 11241125 through 1129 11291130 through 1133 1133

Strona 232

AT-S73 and AT-S99 Management Software User’s Guide3071259 through 1264 12641265 through 1269 12691270 through 1275 12751276 through 1281 12811282 thro

Strona 233

Appendix C: Packet Rate Limiting on the AT-CM2K0S Line Card3081436 through 1443 14431444 through 1450 14501451 through 1457 14571458 through 1465 1465

Strona 234

AT-S73 and AT-S99 Management Software User’s Guide3091671 through 1680 16801681 through 1690 16901691 through 1700 17001701 through 1710 17101711 thro

Strona 235 - Testing the Feature

AT-S73 and AT-S99 Management Software User’s Guide312. After the line card initializes its software, it queries for a management card over the backpla

Strona 236

Appendix C: Packet Rate Limiting on the AT-CM2K0S Line Card3101999 through 2012 20122013 through 2026 20262027 through 2040 20402041 through 2055 2055

Strona 237 - Configuring SNMPv3

AT-S73 and AT-S99 Management Software User’s Guide3112485 through 2506 25062507 through 2528 25282529 through 2551 25512552 through 2574 25742575 thro

Strona 238 - SNMPv3 Overview

Appendix C: Packet Rate Limiting on the AT-CM2K0S Line Card3123285 through 3322 33223323 through 3361 33613362 through 3401 34013402 through 3442 3442

Strona 239

AT-S73 and AT-S99 Management Software User’s Guide3134843 through 4926 49264927 through 5012 50125013 through 5102 51025103 through 5194 51945195 thro

Strona 240

Appendix C: Packet Rate Limiting on the AT-CM2K0S Line Card3149217 through 9523 95239524 through 9852 98529853 through 10204 1020410205 through 10582

Strona 241 - Notification

AT-S73 and AT-S99 Management Software User’s Guide315142858 through 250000 285714Table 37. Rate Limits Equivalents (Continued)Specified Rate Limit (Kb

Strona 242 - SNMPv3 Access Table

Appendix C: Packet Rate Limiting on the AT-CM2K0S Line Card316

Strona 243

317IndexNumerics10/100Base-TX portconfiguring 107described 22restoring default settings 112Aactivity monitordescribed 23displaying 104AT-CM Line Cards

Strona 244

Index318dying gaspconfiguring AT-CM Line Cards for 230described 52testing 235Eevent logdescribed 23displaying 98Fflow control 139IIP address configura

Strona 245 - SNMPv3 Target Address Table

AT-S73 and AT-S99 Management Software User’s Guide319resettingAT-CM Line Cards 162AT-CV5M02 Management Card 96Sserial numbers 167SFP information 170Sm

Strona 246

Chapter 1: AT-CV5M02 Management Card32instructions can be found in “Restoring the Last Saved Configuration” on page 181.  You have to configure a rem

Strona 248

AT-S73 and AT-S99 Management Software User’s Guide33(The incrementing number at the bottom of the screen is the ID number of the parameter setting the

Strona 249

Chapter 1: AT-CV5M02 Management Card34Converteon ChassisTable 1 lists the four chassis in the Converteon product line.The AT-CV1200 Chassis and AT-CV1

Strona 250

35Chapter 2AT-CM and AT-CV Media Converter Line CardsThe sections in this chapter are: “AT-CM Media Converter Line Cards” on page 36 “AT-CV Media Co

Strona 251

Chapter 2: AT-CM and AT-CV Media Converter Line Cards36AT-CM Media Converter Line CardsThe AT-CM Line Cards are two-port Fast Ethernet and Gigabit Eth

Strona 252

AT-S73 and AT-S99 Management Software User’s Guide37Table 1 lists the line cards in this series.Table 1. AT-CM Media Converter Line CardsLine CardType

Strona 253

Chapter 2: AT-CM and AT-CV Media Converter Line Cards38NoteThe maximum operating distances of the fiber optic ports assume full-duplex operation. The

Strona 254

AT-S73 and AT-S99 Management Software User’s Guide39The AT-CM70S Line Card is an exception to this rule because it has an RS-232 port for local manage

Strona 255

Contents4OAM-based Features...

Strona 256

Chapter 2: AT-CM and AT-CV Media Converter Line Cards40AT-CV Media Converter Line CardsThe AT-CV Line Cards are two-port media converters. They have a

Strona 257

AT-S73 and AT-S99 Management Software User’s Guide41NoteThe maximum operating distances of the fiber optic ports assume full-duplex operation. The dis

Strona 258

Chapter 2: AT-CM and AT-CV Media Converter Line Cards42Operating ModesThe AT-CM Line Cards support these operating modes: Link Test mode MissingLink

Strona 259

AT-S73 and AT-S99 Management Software User’s Guide43MissingLinkModeThe two ports of a media converter line card operating in this mode share their “li

Strona 260

Chapter 2: AT-CM and AT-CV Media Converter Line Cards44and their status in the management software will be Online. If one or both ports cannot establi

Strona 261

AT-S73 and AT-S99 Management Software User’s Guide45running a spanning tree protocol, the protocol might become confused as the status of the device’s

Strona 262

Chapter 2: AT-CM and AT-CV Media Converter Line Cards46OAM-based FeaturesThe AT-CM Line Cards support five OAM-based features on their fiber optic por

Strona 263

AT-S73 and AT-S99 Management Software User’s Guide47Figure 1. Remote Peer Management - Example 1This feature is supported on all of the Converteon cha

Strona 264

Chapter 2: AT-CM and AT-CV Media Converter Line Cards48Figure 2. Remote Peer Management - Example 2You can manage the remote line cards from the menus

Strona 265

AT-S73 and AT-S99 Management Software User’s Guide49Figure 3. Remote Module Status and Configuration MenuThe corresponding window in the web browser w

Strona 266

AT-S73 and AT-S99 Management Software User’s Guide5Restoring the Default Setting on the 10/100Base-TX Port ...

Strona 267

Chapter 2: AT-CM and AT-CV Media Converter Line Cards50Remote Updatesof the AT-S73ManagementSoftwareAllied Telesis may periodically release new versio

Strona 268

AT-S73 and AT-S99 Management Software User’s Guide51OAM LoopbackTestsOAM loopback tests are used to test the quality of the fiber optic connection tha

Strona 269

Chapter 2: AT-CM and AT-CV Media Converter Line Cards52Dying GaspFeatureDying gasp is a signal that AT-CM Line Cards in the AT-CV1203 Chassis transmit

Strona 270

AT-S73 and AT-S99 Management Software User’s Guide53Figure 8. 1st Failure SignalNoteAll of the AT-CM Line Cards support the 1st failure signal, except

Strona 271 - Chapter 11

Chapter 2: AT-CM and AT-CV Media Converter Line Cards54Refer to Table 4 for the required version numbers of the management software. If you install

Strona 272 - Overview

AT-S73 and AT-S99 Management Software User’s Guide55OAM VariableRequestsThis feature is part of the IEEE 802.3ah Ethernet OAM standard. It allows you

Strona 273 - Configuring the TFTP Client

Chapter 2: AT-CM and AT-CV Media Converter Line Cards56OAM ClientSettingsTable 5 lists the parameter settings for the OAM clients on the AT-CM Line Ca

Strona 274

57Chapter 3Starting a Management SessionThis chapter has the following sections: “Starting a Local Management Session” on page 58 “Starting a Telnet

Strona 275

Chapter 3: Starting a Management Session58Starting a Local Management SessionThis procedure explains how to start a local, out-of-band management sess

Strona 276

AT-S73 and AT-S99 Management Software User’s Guide594. When prompted, enter the username and password of the manager or operator account on the manage

Strona 277

Contents6Displaying the MAC Addresses and Serial Numbers...

Strona 278

Chapter 3: Starting a Management Session60The instructions in Table 6 explain how to move through the menus and select menu options.Activated options

Strona 279

AT-S73 and AT-S99 Management Software User’s Guide61Starting a Telnet Management SessionNoteThe requirements for remote Telnet management are listed i

Strona 280

Chapter 3: Starting a Management Session62Starting a Web Browser Management SessionNoteThe requirements for remote web browser management are listed i

Strona 281

AT-S73 and AT-S99 Management Software User’s Guide63Figure 12. Chassis View

Strona 282

Chapter 3: Starting a Management Session64Saving Your Configuration ChangesThis section explains the save commands in the AT-S99 Management Software o

Strona 283

AT-S73 and AT-S99 Management Software User’s Guide65The same commands in the web browser windows are found in the Files tab of the Configuration windo

Strona 284 - TFTP Server IP Address-> _

Chapter 3: Starting a Management Session66The web browser windows also have this command for local and remote line cards. Figure 16 shows the location

Strona 285

AT-S73 and AT-S99 Management Software User’s Guide67 Save Line Card Configuration (menus) and Save Current Configuration (web browser windows) - Thes

Strona 286

Chapter 3: Starting a Management Session68The functions of these commands are given here: Copy Active Card Configuration to Standby Card - This comma

Strona 287 - Software Programs

AT-S73 and AT-S99 Management Software User’s Guide69What to Configure First on the AT-CV5M02 Management CardThis section has a few suggestions on what

Strona 288

AT-S73 and AT-S99 Management Software User’s Guide7Configuring SNMPv3 Entities ...

Strona 289

Chapter 3: Starting a Management Session70Assigning an IPAddressConfigurationand Changing theCommunityStringsThe management card has to be assigned an

Strona 290

AT-S73 and AT-S99 Management Software User’s Guide71 A default gateway address is needed if the management card will be communicating with a network

Strona 291 - SNMPv3 Configuration Examples

Chapter 3: Starting a Management Session723. From the System Configuration Menu, select System Clock Configuration. 4. To set the date and time manual

Strona 292 - Configure SNMPv3 Group Table

AT-S73 and AT-S99 Management Software User’s Guide73For further instructions on how to configure the management card, refer to Chapter 4, ”Configuring

Strona 293 - Operator

Chapter 3: Starting a Management Session74Configuring the AT-CM Media Converter Line Cards for the OAM-based FeaturesAre you planning to implement any

Strona 294 - Worksheet

AT-S73 and AT-S99 Management Software User’s Guide754. In the Module Status and Configuration Menu, examine the operating mode of the line card in the

Strona 295

Chapter 3: Starting a Management Session769. Type Y for yes to update the master configuration file on the management card with the new setting for th

Strona 296

AT-S73 and AT-S99 Management Software User’s Guide7717. Return to the Main Menu.18. The line card is now configured for the OAM-based features. If you

Strona 297

Chapter 3: Starting a Management Session7821. Return to the line card’s Module Configuration Menu.22. To configure other parameters on the line card,

Strona 298

79Chapter 4Configuring the AT-CV5M02 Management CardThis chapter has the following sections: “Assigning an IP Address Configuration” on page 80 “Ass

Strona 299

Contents8

Strona 300

Chapter 4: Configuring the AT-CV5M02 Management Card80Assigning an IP Address ConfigurationThis section explains how to assign an IP address, subnet m

Strona 301

AT-S73 and AT-S99 Management Software User’s Guide813. From the System Configuration Menu, select IP Parameters to display the IP Parameters Menu show

Strona 302

Chapter 4: Configuring the AT-CV5M02 Management Card82Here are the guidelines to the DHCP client: The 10/100Base-TX port on the AT-CV5M02 Management

Strona 303

AT-S73 and AT-S99 Management Software User’s Guide83Figure 23. System Tab3. Click Edit in the IP Parameters section of the window to display the IP Pa

Strona 304

Chapter 4: Configuring the AT-CV5M02 Management Card84hop to reaching the remote subnet and has to be a member of the same subnet as the card’s IP add

Strona 305

AT-S73 and AT-S99 Management Software User’s Guide85Assigning a NameBy assigning a name to the management card, you make the card and the chassis easi

Strona 306

Chapter 4: Configuring the AT-CV5M02 Management Card86Assigning Contact and Location InformationMenus To enter the chassis’ location and the name of t

Strona 307

AT-S73 and AT-S99 Management Software User’s Guide87Figure 24. SNMPv1 & SNMPv2c Tab3. To change the contact and location information, click Edit t

Strona 308

Chapter 4: Configuring the AT-CV5M02 Management Card88Configuring the SNMP Community StringsThe procedures in this section are used to set the three S

Strona 309

AT-S73 and AT-S99 Management Software User’s Guide89Specifying the IP Addresses of SNMP Trap ReceiversThe management card can send SNMP traps to up to

Strona 310

9Figure 1. Updating the Master Configuration File on a Standby Card ...

Strona 311

Chapter 4: Configuring the AT-CV5M02 Management Card90Configuring Management SecurityThe AT-S99 Management Software on the AT-CV5M02 Management Card h

Strona 312

AT-S73 and AT-S99 Management Software User’s Guide914. Configure the parameters as needed. The options are described in Table 7.Table 7. Omega Options

Strona 313

Chapter 4: Configuring the AT-CV5M02 Management Card925. To save your changes in the master configuration file, return to the Configuration Menu and s

Strona 314

AT-S73 and AT-S99 Management Software User’s Guide93Manually Setting the Date and TimeTo manually set the date and time on the management card, perfor

Strona 315

Chapter 4: Configuring the AT-CV5M02 Management Card94Web Browser To manually set the date and time from the web browser windows:1. Select Configurati

Strona 316

AT-S73 and AT-S99 Management Software User’s Guide95Configuring the Network Time Protocol ClientThe AT-CV5M02 Management Card has an NTP client for se

Strona 317 - Numerics

Chapter 4: Configuring the AT-CV5M02 Management Card96Resetting the Management CardThis procedure is used to reset the management card in the chassis.

Strona 318

AT-S73 and AT-S99 Management Software User’s Guide97Web Browser To reset the management card from the web browser windows:1. Select Module Status and

Strona 319

Chapter 4: Configuring the AT-CV5M02 Management Card98Viewing the Event LogFor background information, refer to “Event Log” on page 23.Menus To displa

Strona 320

AT-S73 and AT-S99 Management Software User’s Guide99Figure 30. Event LogThe columns in the event log are described in Table 8.ConverteonEvent LogTotal