TurboStack ΤΜ AT-TS06F/ST, SC, SMAT-TS08AT-TS12F/ST, SC, SMAT-TS12TAT-TS12TRAT-TS24TAT-TS24TREthernet Hubswith ManagementInstallation Manual TS/HW_Ti
viii ELEKTRISKT—ANMÄRKNING BETRÄFFANDE KABELNAnvänd en kabel med maximum längd 4,5 meter och minimum 6 amp nominal, 250V, av HAR kabelfabrikat med et
TurboStack ΤΜ AT-TS06F/ST, SC, SMAT-TS08AT-TS12F/ST, SC, SMAT-TS12TAT-TS12TRAT-TS24TAT-TS24TREthernet Hubswith ManagementInstallation Manual
Copyright 1996 Allied Telesyn InternationalAll rights reserved. No part of this publication may be reproduced without prior written permission fro
xi Table of Contents Electrical Safety and Installation Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
xii Hub Connection Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
xiii Chapter 8AT-TS24T Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
xiv Appendix FTurboStack™ Manual Feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
xv Figure 41: AT-TS12T Faceplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 Chapter 1 Overview This manual describes the hardware features and installation procedures for ATI’s set of independently manageable TurboStack™ (T
Overview2 The TurboStack department concentrator chassis can be configured to connect hubs across a standard (or non-segmented) backplane. In this con
Copyright 1996 Allied Telesyn InternationalAll rights reserved. No part of this publication may be reproduced without prior written permission fro
TurboStack Hubs with Management3❑ Three types of network management capability:— SNMP— Via ASYNC ASCII terminal port (Omega)— Telnet (Omega)❑ Software
Overview4Hubs withoutManagementIn addition to the TurboStack hubs with management, ATI offers six models without management (i.e., Slave modules). Whe
TurboStack Hubs with Management5You can use any combination of TurboStack and AT-3600 Series hubs in the same department concentrator. In this configur
Overview6In the seven-slot department concentrator shown in Figure 2, up to 90 ports can be monitored:❑ One Master containing eight 10BASE2 station po
TurboStack Hubs with Management7Chassis OptionsATI offers a variety of desktop and rackmount chassis. These chassis are available with either standard
Overview8Chassis withSegmentedBackplaneIn a 7-slot segmented backplane chassis, you can install up to six TurboStack hubs (i.e., one Master and five ma
TurboStack Hubs with Management9Network ManagementNetworkManagementPlanningBefore installing and connecting manageable TurboStack hubs at various site
Overview10MAC Address Every “intelligent” ATI hub (i.e., hubs with management capability) is provided with a factory-installed unique 6-byte (12-digit
11Chapter 2Hardware InstallationSite PreparationAttentionImproper installation of the chassis can expose personnel to high voltages, risking the possi
Hardware Installation12Installing HubsThis section contains two separate procedures for installing manageable TurboStack hubs:❑ Standalone installatio
i Electrical Safety and Installation Requirements RADIATED ENERGY U.S. Federal CommunicationsNote: This equipment has been tested and found to compl
TurboStack Hubs with Management131. Every TurboStack hub is shipped with a dust cover on the interrepeater bus port, located on the back of the TurboS
Hardware Installation14NoteWhen inserting or removing repeater modules (using the hot swapping method), you must be sure that the power cord is plugge
TurboStack Hubs with Management1510. Secure the module in the chassis slot by screwing the module in place (see Figure 9). Then, snap closed the plast
Hardware Installation16NoteIf you have configured your chassis with both AT-3600 Series modules and TurboStack modules, you will need to refer to the
TurboStack Hubs with Management17The principal use for the RS232 port is connection of a local network management terminal to access Omega. For more i
Hardware Installation18You can combine any TurboStack hub model type with any of the six network port appliqués listed in Table 3.Table 3: ATI Network
TurboStack Hubs with Management19Network Appliqué InstallationIn a TurboStack department concentrator chassis, you can connect manageable hubs to netw
Hardware Installation202. Detach the AUI appliqué assembly from the hub faceplate by loosening the two M3x6 flat-head screws to the far right and left
TurboStack Hubs with Management215. Separate the AUI appliqué connector plate (shown in Figure 15) from the ribbon cable (shown in Figure 16) by rotat
Hardware Installation223. Secure the interface between the replacement appliqué and the AUI connector by using 4-40 pan-head screws as shown in Figure
ii NORMEN: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen. Hochfrequenzstörung EN55022 Klasse A WARNUNG: Bei Verwendung zu Hause
TurboStack Hubs with Management23To remove a 10BASE2, 10BASE-T or fiber Optic (10BASE-FL) appliqué1. Snap off the plastic cover plate on the installed
Hardware Installation24LED DisplaysTurboStack hubs have two types of LED displays:❑ Hub status indicators show the overall condition of the module❑ Po
TurboStack Hubs with Management25Troubleshooting the InstallationThis section provides a checklist for resolving problems associated with your hub and
27Chapter 3AT-TS06F/ST, SC, SM ConnectivityAT-TS06F/ST, SC, SM ModulesATI offers three 6-port fiber optic hubs with management capability. The only phy
AT-TS06F/ST, SC, SM Connectivity28Figure 22, Figure 23 and Figure 24 show faceplates for each of the three types of hub modules.Figure 22: AT-TS06F/ST
TurboStack Hubs with Management29NoteReferences in this manual to SMA and SM are interchangeable, both being acronyms for Sub Miniature Assembly.Fiber
AT-TS06F/ST, SC, SM Connectivity30Fiber OpticConnectorsFiber optic repeaters use one pair of ST, one pair of SC, or one pair of SM type connectors per
TurboStack Hubs with Management31Figure 27 shows the threaded SM connectors.Port IndicatorsThe port indicators on the AT-TS06F/ST, SC, SM Series repea
AT-TS06F/ST, SC, SM Connectivity32AMBER PARTITION—Steady illumination indicates that the port has a valid link and is partitioned.AMBER COLLISION—Flas
33Chapter 4AT-TS08 ConnectivityAT-TS08 ModulesThe AT-TS08 SNMP-managed hub has eight 10BASE2 ports with BNC connectors. Figure 29 shows the AT-TS08 fa
iii ELEKTRISK—LEDNINGAnvend ledning af maksimum 4,5 meters længde, med en kapacitet på minimum 6 amp., 250 v, bestående af en IEC 320 connector med
AT-TS08 Connectivity34Normal Cascade Port 8 is a dual-purpose port and has the label “NORMAL/CASCADE.” You can use it in the following ways:❑ To conne
TurboStack Hubs with Management35If you are installing a coaxial cable segment without a BNC-T connector at the end (as shown in Figure 32), you must
AT-TS08 Connectivity36Terminator Switch Figure 33 shows the location of the 50 Ω Terminator switch included with each BNC port receptacle:0 = Terminat
37Chapter 5AT-TS12F/ST, SC, SM ConnectivityAT-TS12F/ST, SC, SM ModulesATI offers three fiber optic managed hubs, each with twelve ports. The only physi
AT-TS12F/ST, SC, SM Connectivity38Figure 34, Figure 35 and Figure 36 show faceplates for each of the three types of hub modules. Figure 34: AT-TS12F/S
TurboStack Hubs with Management39NoteReferences in this manual to SMA and SM are interchangeable, both being acronyms for Sub Miniature Assembly.Fiber
AT-TS12F/ST, SC, SM Connectivity40Fiber OpticConnectorsFiber optic repeaters use one pair of ST, one pair of SC, or one pair of SM type connectors per
TurboStack Hubs with Management41Figure 39 shows the threaded SM connectors.Port IndicatorsThe port indicators and corresponding symbopls on the AT-TS
AT-TS12F/ST, SC, SM Connectivity42AMBER COLLISION—Flashing illumination indicates that the port has a valid link and that there are collisions on the
43Chapter 6AT-TS12T ConnectivityAT-TS12T ModulesThe AT-TS12T has 12 10BASE-T ports incorporated in a Telco 50-pin (RJ21) connector for UTP. Figure 41
iv SECURITE INFORMATION SUR L’ELECTRICITEAVERTISSEMENT: DANGER D’ELECTROCUTIONPour empêcher les dangers d’ELECTROCUTION, ne pas enlever le couvercle.
AT-TS12T Connectivity4450-Pin Telco ReceptacleThe RJ21 50-pin Telco receptacle on the AT-TS12T and AT-TS24T Repeaters is configured as shown in Figure
TurboStack Hubs with Management45GREEN LINK (Steady Green)—This indicates that the particular port has a valid link and is not partitioned.GREEN RECEI
47Chapter 7AT-TS12TR ConnectivityAT-TS12TR ModulesThe AT-TS12TR has 12 10BASE-T ports represented by 12 RJ45 connectors for UTP. Figure 44 shows the A
AT-TS12TR Connectivity48RJ45 ConnectorsThe AT-TS12TR uses 12 RJ45 connectors, thus eliminating the need for a Telco-type cabling adapter. Figure 45 sh
49Chapter 8AT-TS24T ConnectivityAT-TS24T ModulesThe AT-TS24T has 24 10BASE-T ports incorporated in two Telco 50-pin (RJ21) receptacles for UTP. Figure
AT-TS24T Connectivity5050-Pin Telco ReceptacleThe 50-pin Telco receptacles on the AT-TS24T hub are configured as shown in Figure 48. For a pin-out tabl
TurboStack Hubs with Management51GREEN LINK (Steady Green)—This indicates that the particular port has a valid link and is not partitioned.GREEN RECEI
53Chapter 9AT-TS24TR ConnectivityAT-TS24TR ModulesThe AT-TS24TR has 24 10BASE-T ports represented by 24 RJ45 connectors for UTP. The ports are double
AT-TS24TR Connectivity54RJ45 ConnectorsThe AT-TS24TR uses 24 RJ45 connectors, thus eliminating the need for a Telco-type cabling adapter. Figure 51 sh
TurboStack Hubs with Management55By setting the MDI/MDI-X switch to MDI, you can connect two hubs via standard straight-through cable. The switch affe
v HUOMAUTUS: Ilmavaihtoreikiä ei pidä tukkia ja niillä täytyy olla vapaa yhteys ympäröivään huoneilmaan, jotta ilmanvaihto tapahtuisi.HUOMAUTUS: ÄLÄ
AT-TS24TR Connectivity56GREEN LINK (Solid Green)—This indicates that the particular port has a valid link and is not partitioned.GREEN RECEIVE (Flashi
57Appendix AUTP ReferenceUTP Wiring Specifications10BASE-T requires UTP wiring capable of supporting 10 Megabit data rates. Use Level 3 or better UTP
UTP Reference58UTP Hub-to-MAUWiringFigure 54 shows a UTP cable with an RJ45 connector. For a 10BASE-T link between a hub and a Medium Attachment Unit
TurboStack Hubs with Management59UTP MAU-to-MAU,Hub-to-Hub Wiring10BASE-T MAU-to-MAU or hub-to-hub wiring generally requires a crossover cable located
61Appendix BTelco ReferenceWiring Specification50-Pin TelcoReceptacleThe RJ21 50-pin Telco receptacle on the AT-TS12T and AT-TS24T Repeaters is configu
Telco Reference62Table 8: 50-Pin Telco Pin-Out 50-Pin ConnectorPin NumberPunch-Down BlockPin NumberCable Color Code1LinkDesignation Hub8-Pin Modular
TurboStack Hubs with Management6340 29 BK-SL 8 RCV POS 115 30 SL-BK 8 RCV NEG 241 31 Y-BL 8 XMT POS 316 32 BL-Y 8 XMT NEG 642 33 Y-OR 9 RCV POS 117 34
Telco Reference64Accessories50-Pin Telco-to-RJ45Octopus CablesThe 10BASE-T ‘octopus’ cable breaks out the AT-TS12T or AT-TS24T Hub 50-pin Telco connec
65Appendix CIEEE 802.3 Quick Primer10BASE-T10BASE-T UTP media were implemented to reduce Ethernet wiring costs. UTP wiring is installed in most buildi
IEEE 802.3 Quick Primer6610BASE-FL/FOIRL EthernetThe IEEE 802.3 10BASE-FL standard supports up to 2,000 meters (6,560 ft.) of multimode duplex fiber o
vi INSTALLASJON ELEKTRISK—AUTO SPENNINGSTILPASSINGDette produktet vil automatisk bli tilpasset hvilken som helst strøminnstilling i de områdene som v
TurboStack Hubs with Management67PropagationPropagation delay is the time it takes a signal to travel from the input of a system component to the outp
69Appendix DGlossary10BASE2—Also called thin Ethernet, thinnet or CheaperNet, a 10 MHz baseband specification. Cable impedance is 50 Ω and maximum coa
Glossary70BAYONET NUT COUPLE (BNC) CONNECTOR—A 10BASE2 thin coax connector with push-on BNC locking lug. This lug quickly locks into place with a half
TurboStack Hubs with Management71DEPARTMENT CONCENTRATOR—Hub that provides a large number of workstation connections. The term department concentrator
Glossary72LINK TEST—In 10BASE-T Ethernet, there is a link test function that validates the UTP link. This consists of a pulse transmitted from point A
TurboStack Hubs with Management73PROPAGATION DELAY—The time required for a signal to travel from the input of a system component to the output. Usuall
Glossary74TCP/IP PROTOCOLS—A set of protocols for intercomputer communication, including network level (Internet Protocol), transport level (Transmiss
75Appendix ETechnical Support Fax OrderName___________________________________________________________________Company ________________________________
77Appendix FTurboStack™ Manual FeedbackPlease tell us what additional information you would like to see discussed in the manual. If there are topics y
79Appendix GWhere To Find UsFor Technical Support or ServiceLocation Phone FaxNorth AmericaUnited States, Canada, Mexico, Central America, South Ameri
vii Emisión RFI EN55022 Clase A ADVERTENCIA: en un entorno doméstico, este producto puede causar radiointerferencias, en cuyo caso, puede requerirs
81Appendix HIndexAaccessories 64adaptersAT-ADAPT-2 64, 69harmonica 71harmonica-style 64octopus 64ambercollision 42, 45, 51, 56partition 41, 45, 51, 56
Index82SC 16, 40SM 16, 40, 41ST 16, 40straight tip (ST) 3, 4, 27, 37, 73sub minature assembly (SMA) 73sub miniature assembly (SMA) 3, 4, 27, 37subscri
TurboStack Hubs with Management83AT-TS12FS/SM 1AT-TS12FS/SMA 4AT-TS12FS/ST 4AT-TS12T 3, 43, 44, 64AT-TS12TR 3, 47, 48AT-TS24 44, 61AT-TS24T 3, 49, 50,
lxxxvAT-TS12TR Faceplate 27-Slot Chassis withSegmented Backplane 58-slot Chassis with Standard Backplane 7SegmentedBackplane (detail) 8Location of MAC
lxxxviAT-TS08 Faceplate 33AT-TS08 Cascade connection 34BNC-T at End of 10BASE2 Segment 35BNC Connector at End of Segment with Internal Termination 35A
lxxxviiTurboStack Hubs with Management 3TurboStack Hubs without Management 4ATI Network Port Appliqués 18ATI Micro Transceivers 18AT-TS06F Hubs with M