AT-MC301AT-MC302AT-MC303Fast Ethernet Media ConvertersInstallation GuidePN 613-10762-00 Rev C
xFor Sales or Corporate InformationTell Us What You ThinkIf you have any comments or suggestions on how we might improve this or other Allied Telesyn
1OverviewThe AT-MC300 Series Fast Ethernet Media Converters are designed to extend the distance of your network by allowing you to interconnect twiste
2Features and ComponentsThe media converter has the following features:❑One 100Base-FX fiber optic port❑One 100Base-TX twisted pair port❑MDI/MDI-X but
AT-MC300 Series Installation Guide3100Base-FX Fiber Optic PortThe 100Base-FX fiber optic port can use either 50/125 or 62.5/125 micron multimode fiber
4MissingLink/Link Test ButtonThe MissingLink/Link Test (M/L ON/LNK TST) button allows you to perform a link test on the ports on the media converter.
AT-MC300 Series Installation Guide5NoteThe MissingLink feature is disabled when the MissingLink/Link Test button is in the Link Test position. Auto-ne
6With auto-negotiation activated on the media converter, the unit will determine that the hub is capable of half-duplex only, and will set the port co
AT-MC300 Series Installation Guide7External AC/DC Power AdapterThe power adapter supplies 12 volts DC to the media converter. Allied Telesyn supplies
8In some network environments, you might need to interconnect two media converters in what is referred to as a back-to-back topology. In this topology
AT-MC300 Series Installation Guide9Installing the AT-MC300 Series Media ConverterThe following sections explain how to install the media converter. Th
Copyright 2000 Allied Telesyn International, Corp.960 Stewart Drive Suite B, Sunnyvale CA 94085, USAAll rights reserved. No part of this publication
10Reviewing Safety PrecautionsPlease review the following safety precautions before you begin to install the media converter.WarningClass 1 laser prod
AT-MC300 Series Installation Guide11Planning the InstallationPlease refer to the following guidelines when planning the installation.❑Both end nodes t
12NoteFor additional technical information on the media converter’s fiber optic port, refer to “Technical Specifications” on page 18.Table 5 Fiber Op
AT-MC300 Series Installation Guide13Installing the UnitThis section contains the procedure for installing the media converter.If you are building a ba
14Figure 7 12 V DC Receptacle on Rear Panel7. Verify that the PWR LED lights green.8. Set the MDI/MDI-X button for the 100Base-TX twisted pair port t
AT-MC300 Series Installation Guide15Verifying the InstallationTo verify the installation and check to be sure that the media converter is operating pr
16TroubleshootingThis section contains guidelines for troubleshooting the media converter. If a problem occurs, set the M/L ON/LNK TST button to the L
AT-MC300 Series Installation Guide17If the LNK LED for the twisted pair port is OFF, verify the following:❑The node connected to the port is powered O
18Technical SpecificationsTable 6 lists the technical specifications for the media converter.Table 6 Technical SpecificationsTable 7 and Table 8 list
AT-MC300 Series Installation Guide19Warranty RegistrationWhen you have finished installing the product, you should register the product by completing
iiiElectrical Safety and Emission StatementStandards: This product meets the following standards.RFI EmissionEN55022 Class A ! 1WARNING: In a domestic
21Appendix ATranslated Safety and Emission InformationImportant: This appendix contains multiple-language translations for the safety statements in th
22Standards: This product meets the following standards.!1RFI Emission EN55022 Class A!2WARNING: In a domestic environment this product may cause radi
AT-MC300 Series Installation Guide23!13OPERATING TEMPERATURE: This product is designed for a maximum ambient temperature of 40° degrees C.!14ALL COUNT
24Standarder: Dette produkt tilfredsstiller de følgende standarder.!1Radiofrekvens forstyrrelsesemission EN55022 Klasse A!2ADVARSEL: I et hjemligt m
AT-MC300 Series Installation Guide25Eisen: Dit product voldoet aan de volgende eisen.!1RFI Emissie EN55022 Klasse A!2WAARSCHUWING: Binnenshuis kan di
26Normes: ce produit est conforme aux normes de suivantes.!1Emission d’interférences radioélectriques EN55022 Classe A!2MISE EN GARDE : dans un envir
AT-MC300 Series Installation Guide27Standardit: Tämä tuote on seuraavien standardien mukainen.!1Radioaaltojen häirintä EN55022 Luokka A!2VAROITUS: Kot
28Standard: Questo prodotto è conforme ai seguenti standard.!1Emissione RFI (interferenza diradiofrequenza) EN55022 Classe A!2AVVERTENZA: in ambient
AT-MC300 Series Installation Guide29Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer.!1RFI stråling EN55022 Klasse A!2ADVA
30Padrões: Este produto atende aos seguintes padrões.!1Emissão de interferência de radiofrequência EN55022 Classe A!2AVISO: Num ambiente doméstico e
AT-MC300 Series Installation Guide31Estándares: Este producto cumple con los siguientes estándares.!1Emisión RFI EN55022 Clase A!2ADVERTENCIA: en un
32Standarder: Denna produkt uppfyller följande standarder.!1Radiostörning EN55022 Klass A!2VARNING: Denna produkt kan ge upphov till radiostörningar
33Appendix BTechnical Support Fax OrderName __________________________________________________________________Company ________________________________
35Appendix CAT-MC300 Series Installation Guide FeedbackPlease tell us what additional information you would like to see discussed in this guide. If th
vElectrical Safety and Emission Statement...iiiWelcome to Allied Telesyn...
Table of ContentsviAppendix ATranslated Safety and Emission Information... 21Appendix BTechnical Support Fax Orde
viiThis guide contains instructions on how to install an AT-MC300 Series Fast Ethernet Media Converter.Where to Find Web-based GuidesThe Allied Telesy
viiiContacting Allied TelesynThere are several ways to contact Allied Telesyn technical support: online, telephone, fax, and e-mail.Online SupportYou
AT-MC300 Series Installation GuideixReturning ProductsProducts for return or repair must first be assigned a Return Materials Authorization (RMA) numb