AlliedView™-EMS 3.10 Device Management Guide Page 285 of 367
Note - Valid MIB Set values for the Administration Status parameter are 'up' and
'down' only.
Note - The Promiscuous Mode parameter is implemented as 'read-only'.
Detail Info
Duplex Mode
Displays the duplex mode of the ports.
Note - Port numbering will vary depending on the number of expansion modules
installed and the bay in which they are installed.
Left Bay Right Bay Numbering
None None 1 to 25 (Port 25 is invalid and should be
ignored.)
None AT-XEM-1XP 1 to 26 (Port 25 will not show any valid
data. Port 26 is invalid and should be
ignored.)
None AT-XEM-12S
AT-XEM-12T
1 to 37 (Ports 25 to 36 are invalid and
should be ignored. Port 37 will show
data for port 1 of the module on the
right bay.)
AT-XEM-1XP None 1 to 26 (Port 25 will show data for the
port on the left bay. Port 26 is invalid
and should be ignored.)
AT-XEM-12S
AT-XEM-12T
None 1 to 37 (Ports 25 to 36 will show data
for ports on the left bay. Port 37 is
invalid and should be ignored.)
AT-XEM-1XP AT-XEM-1XP 1 to 27 (Port 25 will show data for the
port on the left bay. Port 26 will not
show any valid data. Port 27 is invalid
and should be ignored.)
AT-XEM-1XP AT-XEM-12S
AT-XEM-12T
1 to 38 (Port 25 will show data for the
port on the left bay. Ports 26 to 36 will
not show any valid data. Ports 37 and 38
will show data for ports 1 and 2 of the
module on the right bay.)
AT-XEM-12S
AT-XEM-12T
AT-XEM-1XP 1 to 38 (Ports 25 to 36 will show data
for ports on the left bay. Port 37 will
show data for the port on the right bay.
Port 38 is invalid and should be ignored.)