AlliedView™-EMS 4.0.2 DEVICE MANAGER USER’S GUIDE Page 105 of 124
RMON Options tab (History Control Parameters)
7.3.7.1 Polling Interval
You can change the polling interval here.
7.3.7.2 Display data type of chart
Specifies how to display data in graphs and charts. You can select one of the following
options.
Because RMON histories are collected by RMON agents and Device Manager only displays
the collected data, settings here are slightly different from other windows. The Polling
Interval here is simply the interval at which Device Manager gets collected data from
RMON agents.
Absolute Value
Displays the sum of values which Device Manager got from the RMON agents,
as shown in the following example.
Data sampled by RMON Data displayed by Device Manager
Sample 1 100 100
Sample 2 50 150
Sample 3 250 400