Secure Ethernet Network Adapter Installation and User’s Guide
33
Connecting the Network Cables
The AT-2712FX/SC and AT-2712LX20/SC adapters have two fiber optic
connectors (transmit and receive) for attaching the system to a compatible
link partner or an IEEE 802.3z compliant Fast Ethernet switch. Both
adapters require a fiber optic cable.
The AT-2912T adapter has one twisted-pair connector which requires a
twisted-pair cable. For pin signals and pinout information, see “10/100/
1000Base-T Twisted-Pair Port Connectors” on page 93.
To connect a network cable to the adapter, perform the following
procedure:
Warning
The fiber optic ports contain a Class 1 LED device. When the ports
are disconnected, always cover them with the provided plug.
Exposed ports may cause skin or eye damage.
1. Connect one end of the cable to the adapter:
For the AT-2912T adapter, connect one end of the twisted-pair
cable to the adapter.
For the AT-2712FX/SC and AT-2712LX20/SC adapters, prepare a
fiber optic cable according to the specifications in Table 3. Connect
one end of the cable to the adapter.
2. Connect the other end of the cable:
For the AT-2912T adapter, connect the other end of the cable to
another twisted pair port.
For the AT-2712FX/SC and AT-2712LX20/SC adapters, connect
the other end of the cable to the appropriate Ethernet fiber optic
port.
Table 3. 1000BASE-SX Fiber Optic Cable Specifications
Port Type Connector Media
Maximum
Distance
Wavelength
1000BASE-SX Fiber Optic 62.5 µm multimode
850 nm
275 meters
(853 feet)
1310 nm
1000BASE-LX Fiber Optic 9.125 µm single mode
1310 nm
10 kilometer
(6.213 miles)
1310 nm