Strona 1 - Installation and Safety Guide

A5 Installation and Safety Guide CoverAT-8600 Series SwitchInstallation and Safety GuideAT-8624T/2MAT-8624PoEAT-8648T/2SP

Strona 2 - AT-8600 Series

Installation & Safety Guide 9• Mount the switch in the rack using standard screws (these are not provided).7. Install SFPsFor the AT-8648T/2SP, yo

Strona 3

10 AT-8600 Series Switch9. Apply AC power to the switchPlug the power cord into the AC power connector. This is on the switch’s rear panel, as shown i

Strona 4

Installation & Safety Guide 11How to Configure the SwitchSome configuration is necessary to enable the switch’s advanced switching capabilities. T

Strona 5

12 AT-8600 Series Switch4. Change password and display help.Change the password as soon as possible because a manager account left with the default pa

Strona 6 - Table of Contents

Installation & Safety Guide 134. Enable IP.enable ip5. Assign the vlan1 interface an IP address in the same subnet as the PC.add ip interface=vlan

Strona 7 - Package Contents

14 AT-8600 Series SwitchLEDs on AT-8600 Series SwitchesThe following tables outline how the switch and expansion modules report faults and operational

Strona 8 - Selecting a Site

Installation & Safety Guide 15Link and Mode LEDs for the AT-8624T/2M switchLED State DescriptionLINK OFF There is no link between the port and the

Strona 9 - How to Install the Switch

16 AT-8600 Series SwitchLink and Mode LEDs for the AT-8624PoE switchLED State DescriptionL/A Status(Top LED)OFF There is no link between the port and

Strona 10

Installation & Safety Guide 17Link and Mode LEDs for the AT-8648T/2SP switchLED State DescriptionLINK OFF There is no link between the port and th

Strona 11 - AT-8624POE

18 AT-8600 Series SwitchSFP and 10/100/1000Base-T LEDs for the AT-8648T/2SP switchLED State DescriptionLINK OFF There is no link between the port and

Strona 12 - How to Configure the Switch

AT-8600 SeriesInstallation & Safety GuideAT-8624T/2MAT-8624PoEAT-8648T/2SP

Strona 13

Installation & Safety Guide 19Documentation and Tools CD-ROMThe Documentation and Tools CD-ROM bundled with each switch contains the complete docu

Strona 14

20 AT-8600 Series SwitchSafetyWARNING: In a domestic environment this product may cause radio interference in which case the user may be required to t

Strona 15

Installation & Safety Guide 21Lithium Battery - Should only be changed by authorised service personnel.CAUTION: Danger of explosion if battery inc

Strona 16

22 AT-8600 Series SwitchVORSICHT: DAS NETZKABEL DIENT ZUM TRENNEN DER STROMVERSORGUNG. ZUR TRENNUNG VOM NETZ, KABEL AUS DER STECKDOSE ZIEHEN.GERÄTE DE

Strona 17

Installation & Safety Guide 23SikkerhedADVARSEL: I et hjemligt miljø kunne dette produkt forårsage radio forstyrrelse. Bliver det tilfældet, påkræ

Strona 18

24 AT-8600 Series SwitchLithium batteri - Bør kun udskiftes af uddannet og kvalificeret tekniker.ADVARSEL : Eksplosionsfare, hvis batteriet udskiftes

Strona 19

Installation & Safety Guide 25BEDRIJFSTEMPERATUUR: De omgevingstemperatuur voor dit produkt mag niet meer bedragen dan 40 graden Celsius.ELEKTRISC

Strona 20

26 AT-8600 Series SwitchÉQUIPEMENT DE CLASSE 1 ÉLECTRIQUECE MATÉRIEL DOIT ÊTRE MIS A LA TERRE. La prise de courant doit être branchée dans une prise f

Strona 21

Installation & Safety Guide 27SÄHKÖÖN LIITTYVIÄ HUOMAUTUKSIAVAROITUS: SÄHKÖISKUVAARAEstääksesi SÄHKÖISKUN älä poista kantta. Sisällä ei ole käyttä

Strona 22 - Sicherheit

28 AT-8600 Series SwitchNorme di SicurezzaAVVERTENZA: in ambiente domestico questo prodotto potrebbe causare radio interferenza. In questo caso potreb

Strona 23

2 AT-8600 Series SwitchAT-8600 Installation & Safety GuideDocument Number C613-000083 REV D.© 2006 Allied Telesis Inc. All rights reserved. No par

Strona 24 - Sikkerhed

Installation & Safety Guide 29ATTENZIONE: CARICAMENTO MECCANICO - Il montaggio del dispositivo sul supporto va effettuato in maniera tale da evita

Strona 25 - Veiligheid

30 AT-8600 Series SwitchFORSIKTIG: Lufteventilene må ikke blokkeres, og må ha fri tilgang til luft med romtemperatur for avkjøling.DRIFTSTEMPERATUR: D

Strona 26 - Sécurité

Installation & Safety Guide 31ELÉTRICO - EQUIPAMENTOS DO TIPO CLASSE 1DEVE SER FEITA LIGAÇÃO DE FIO TERRA PARA ESTE EQUIPAMENTO. O plugue de alime

Strona 27 - Turvallisuus

32 AT-8600 Series SwitchAVISOS ELECTRICOSADVERTENCIA: PELIGRO DE ELECTROCHOQUEPara evitar un ELECTROCHOQUE, no quite la tapa. No hay ningún componente

Strona 28

Installation & Safety Guide 33SäkerhetVARNING: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket kan tvinga användaren till att vi

Strona 29 - Norme di Sicurezza

34 AT-8600 Series SwitchLitium batteri - Får endast bytas av utbildade och kvalificerade tekniker.VARNING: Risk för explosion om felaktigt batteri anv

Strona 30 - Sikkerhet

Installation & Safety Guide 35EC Declaration of ConformityWe: ALLIED TELESIS LABS LIMITED27 NAZARETH AVENUECHRISTCHURCH 8024NEW ZEALANDDeclare und

Strona 32 - Seguridad

A5 Installation and Safety Guide CoverAT-8600 Series SwitchInstallation and Safety GuideAT-8624T/2MAT-8624PoEAT-8648T/2SP

Strona 33

Installation & Safety Guide 3Electrical Safety and Emission Compliance StatementSTANDARDS: This product meets the following standards:Category App

Strona 34 - Säkerhet

4 AT-8600 Series SwitchElectrical SafetyIMPORTANT: This equipment must be installed in accordance with safety precautions (page 20).Elektrische Sicher

Strona 35

Installation & Safety Guide 5Table of ContentsElectrical Safety and Emission Compliance Statement ... 3

Strona 36 - EC Declaration of Conformity

6 AT-8600 Series SwitchModels Covered By This GuideThis Installation & Safety Guide includes information on these models: AT-8624T/2M 24-port 10B

Strona 37

Installation & Safety Guide 7Selecting a SiteYou can install the switch in a standard 19-inch rack, on a level surface such as a desktop or bench,

Strona 38

8 AT-8600 Series SwitchHow to Install the SwitchWarning All versions of this equipment must be earthed.Prepare to install the switch1. Read the safety