Allied-telesis AT-GS2002/SP Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Allied-telesis AT-GS2002/SP. Allied Telesis AT-GS2002/SP User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Installation Guide

PN 613-001759 Rev. AAT-GS2002/SPGigabit Ethernet to Fiber SFP Media ConverterAT-GS2002/SP Media Converter Installation Guide

Strona 2

Tables10

Strona 3 - Standards

11PrefaceThis guide contains the installation instructions for the AT-GS2002/SP Media Converter. This preface contains the following sections:❒ “Symbo

Strona 4 - Translated Safety Statements

12Symbol ConventionsThis document uses the following conventions:NoteNotes provide additional information.CautionCautions inform you that performing o

Strona 5 - Contents

AT-GS2002/SP Gigabit Ethernet to Fiber SFP Media Converter Installation Guide13Contacting Allied TelesisIf you need assistance with this product, you

Strona 7

15Chapter 1OverviewThis chapter describes the AT-GS2002/SP Media Converter in the following sections: “Introduction” on page 16 “Front and Back Pane

Strona 8

Chapter 1: Overview16IntroductionThe AT-GS2002/SP Media Converter is a 10/100/1000Base-TX copper to SFP (Small Form-factor Pluggable) media converter.

Strona 9

AT-GS2002/SP Gigabit Ethernet to Fiber SFP Media Converter Installation Guide17SFP Port Here are the features of the SFP port: 1 Port 100BaseX and 1

Strona 10

Chapter 1: Overview18Dimensions Here are the physical dimensions of the AT-GS2002/SP Media Converter: Width - 105 mm (4.12 in), Depth - 95mm (3.75 in

Strona 11

AT-GS2002/SP Gigabit Ethernet to Fiber SFP Media Converter Installation Guide19Front and Back PanelsFigure 1 illustrates the front panel of the AT-GS2

Strona 12 - Symbol Conventions

Copyright © 2012 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied

Strona 13 - Contacting Allied Telesis

Chapter 1: Overview20Twisted-Pair PortsThe AT-GS2002/SP Media Converter features one twisted-pair port that is 10Base-T, 100Base-TX, and 1000Base-T co

Strona 14

AT-GS2002/SP Gigabit Ethernet to Fiber SFP Media Converter Installation Guide21Auto-NegotiationModeWhen the Auto-Negotiation feature is enabled on the

Strona 15 - Overview

Chapter 1: Overview22SFP PortThe AT-GS2002/SP Media Converter features one SFP port. This port is labeled “Port 1” on the front panel. Refer to Figure

Strona 16 - Introduction

AT-GS2002/SP Gigabit Ethernet to Fiber SFP Media Converter Installation Guide23LEDsThere are four types of LEDs on the AT-GS2002/SP Media Converter, a

Strona 17

Chapter 1: Overview24MODE LEDs The MODE LEDs indicate the operating status of the three operation modes: Link Test (LT), MissingLink (ML), and Smart M

Strona 18 - Conditions

AT-GS2002/SP Gigabit Ethernet to Fiber SFP Media Converter Installation Guide25Twisted-Pair PortLEDsThe twisted-pair port LEDs indicate the operating

Strona 19 - Front and Back Panels

Chapter 1: Overview26Fiber Optic PortLEDs (SFP Slot)The fiber optic port (Port 1) LEDs indicate the operating status of the SFP slot on the AT-GS2002/

Strona 20 - Twisted-Pair Ports

AT-GS2002/SP Gigabit Ethernet to Fiber SFP Media Converter Installation Guide27Power SupplyOne multi-region 12VDC AC/DC power adapter is supplied in t

Strona 21 - Back Pressure

Chapter 1: Overview28

Strona 22 - SFP Port

29Chapter 2InstallationThis chapter contains the following sections: “Safety Precaution Review” on page 30 “Site Selection” on page 32 “Unpacking t

Strona 23

3Electrical Safety and Emissions StandardsThis product meets the following standards.RFI Emissions FCC Class B, CISPR 22 Class B, EN55022 Class B, EN5

Strona 24 - Chapter 1: Overview

30Safety Precaution ReviewPlease review the following safety precautions before you begin to install the chassis or any of its components.NoteThe  in

Strona 25 - Twisted-Pair Port

AT-GS2002/SP Gigabit Ethernet to Fiber SFP Media Converter Installation Guide31WarningOperating Temperature. This product is designed for a maximum am

Strona 26 - LEDs (SFP Slot)

Chapter 2: Installation32Site SelectionObserve the following requirements when choosing a site for your installation If you plan to install the AT-GS

Strona 27 - Power Supply

AT-GS2002/SP Gigabit Ethernet to Fiber SFP Media Converter Installation Guide33Unpacking the AT-GS2002/SP Media ConverterTo unpack the AT-GS2002/SP Me

Strona 28

Chapter 2: Installation34Rear Panel DIP Switches ConfigurationBefore the AT-GS2002/SP Media Converter is installed, the rear panel DIP switches must b

Strona 29 - Installation

AT-GS2002/SP Gigabit Ethernet to Fiber SFP Media Converter Installation Guide35SFP Transceiver InstallationTo install an SFP transceiver, perform the

Strona 30 - Safety Precaution Review

Chapter 2: Installation36NoteSFP transceivers are dust sensitive. Always keep the protective plug in the optical bore when a fiber optic cable is not

Strona 31

AT-GS2002/SP Gigabit Ethernet to Fiber SFP Media Converter Installation Guide37Desktop InstallationYou may install the AT-GS2002/SP Media Converter on

Strona 32 - Site Selection

Chapter 2: Installation38Wall Mount InstallationFor a wall mount installation, you must first install the AT-GS2002/SP into an AT-TRAY1 Rack/Wall Moun

Strona 33 - Four rubber protective feet

AT-GS2002/SP Gigabit Ethernet to Fiber SFP Media Converter Installation Guide39Rack Mount InstallationFor a rack mount installation of the AT-GS2002/S

Strona 34

Electrical Safety and Emissions Standards4Translated Safety StatementsImportant: The  indicates that a translation of the safety statement is availab

Strona 35 - SFP Transceiver Installation

Chapter 2: Installation40Cable InstallationObserve the following guidelines when connecting twisted-pair and fiber optic cables to the ports on the me

Strona 36

AT-GS2002/SP Gigabit Ethernet to Fiber SFP Media Converter Installation Guide41Connecting to theSFP ModuleTo connect to the SFP transceiver on the AT-

Strona 37 - Desktop Installation

Chapter 2: Installation42When attaching a optical cable, be sure to observe the following guidelines: Be sure that the cable connector is firmly lock

Strona 38 - Wall Mount Installation

AT-GS2002/SP Gigabit Ethernet to Fiber SFP Media Converter Installation Guide43Powering On the AT-GS2002/SP Media Converter To power on an AT-GS2002/S

Strona 39 - Rack Mount Installation

Chapter 2: Installation443. Plug the AC/DC adapter to a power outlet, as shown in Figure 12. Refer to Appendix A, “Technical Specifications” on page 4

Strona 40 - Cable Installation

AT-GS2002/SP Gigabit Ethernet to Fiber SFP Media Converter Installation Guide45Chapter 3TroubleshootingThis chapter contains information on how to tro

Strona 41 - SFP Module

Chapter 3: Troubleshooting46Power LED is OffProblem: The POWER LED on the front of the media converter is off.Solutions: The unit is not receiving pow

Strona 42

AT-GS2002/SP Gigabit Ethernet to Fiber SFP Media Converter Installation Guide47Twisted-Pair Port LINK/ACT LED is Off Problem: A twisted-pair port on t

Strona 43 - Input Connector

Chapter 3: Troubleshooting48SFP Port LINK/ACT LED Off Problem: The LINK/ACT LED for an SFP transceiver is off.Solutions: The fiber optic port on the t

Strona 44

AT-GS2002/SP Gigabit Ethernet to Fiber SFP Media Converter Installation Guide49Appendix ATechnical SpecificationsThe following specifications are for

Strona 45 - Troubleshooting

5Electrical Safety and Emissions Standards ...

Strona 46 - Power LED is Off

Appendix A: Technical Specifications50Safety and Electromagnetic Emissions CertificationsConnectors and Port PinoutsThis section lists the connectors

Strona 47

AT-GS2002/SP Gigabit Ethernet to Fiber SFP Media Converter Installation Guide51Table 13 lists the RJ-45 connector pins and their MDI/MDI-X pin signals

Strona 48 - SFP Port LINK/ACT LED Off

Appendix A: Technical Specifications52

Strona 49 - Technical Specifications

Contents6Physical Specifications ...

Strona 50 - Connectors and Port Pinouts

7Figure 1. AT-GS2002/SP Front Panel ...

Strona 51

Figures8

Strona 52

9Table 1. twisted-pair Cable Specifications for the AT-GS2002/SP .....................