q Refer to Table 5 for the twisted pair cabling specifications.
Table 5 Twisted Pair Port Specifications
q Refer to Table 6 for the thinnet cabling specifications.
Table 6 Thinnet Port Specifications
q Refer to Table 7 and Table 8 for the fiber optic cabling specifications.
Table 7 Fiber Optic Port Specifications (Full-duplex)
Model Cable Maximum Operating Distance
All models Shielded or unshielded Category 3
or better
100 m (328 ft)
Model Cable Maximum Operating Distance
AT-MC15 Shielded or unshielded Category 3
or better
185 m (606 ft)
Model Connector Cable
Maximum Operating
Distance
Maximum
Allowable Loss
Budget
AT-MC13 ST 62.5/125 micron
multimode
2 km (1.2 mi)
1
1. Maximum operating distance over multimode fiber is 2 km (1.2 mi) if the maximum measured optical loss budget
is less than 20 dB’s when measured at 850 nm optical wavelength.
20 dB at 850 nm
AT-MC14 SC 62.5/125 micron
multimode
2 km (1.2 mi)
1
20 dB at 850 nm
AT-MC16 ST 9/125 micron
single-mode
15 km (9.3 mi) 13 dB at 1310 nm