User-defined menu items can be created to perform one of the following actions.
MIB display
Displays MIB variables of your choice in the common GUI window.
Note - It takes times to get values for many variables. To improve performance,
you can limit the number of variables to be displayed to about 10. You can further
improve performance by increasing the polling interval when the volume of the
data is high.
MIB display
MIB set
Sets a value for the MIB variable. Specify a variable and a value to set. You must
specify the variable with an instance number. For example, ‘sysDescr.0’ or
‘rptrMonitorPortEntry.1.8’ are valid examples. If you specify a variable without
an instance such as 'sysDescr', the set operation cannot be performed.
Note - The MIB set operation changes the data structure in the device's SNMP
agent. Take care when using this function.