Allied-telesis AT-FS724 Instrukcja Użytkownika Strona 45

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 68
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 44
$70;)6:4;#DQG#$70)6:57#,QVWDOODWLRQ#*XLGH
3-5
If the port is
Disabled
, someone has manually disabled the
port for a specific reason. Verify that the reason no longer
exists before you enable this port.
5. Verify that the Link LED is On. For the AT-FS718 with the AT-A11,
the transmit pair must be connected to the receive pair on the
attached device. If the Link LED is
Off
, reverse the transmit and
receive pair at the attached device.
6. Contact Allied Telesyn Technical Support for help.
32:(5#/('#LV
2II
If there is no power to the switch, it cannot function.
A
POWER
LED that is
off
may indicate:
A loose power cord.
Power supply failure, malfunction, or loss of power to the
power supply.
A power supply voltage below acceptable levels.
A high switch temperature due to fan failure or ambient
temperature extreme.
Perform the following steps in sequence; you need not proceed to
the next step if the problem is resolved:
1. Secure the power cord to the power source and check the
POWER
LED to see if it is
on
.
2. Ensure that the voltage is within the required levels in your region.
3. Contact Allied Telesyn Technical Support for help.
)$8/7#/('#LV
2Q
This might indicate a problem with the switch, such as:
Power-on diagnostics has failed
Perform the following steps in sequence; you need not proceed to
the next step if the problem is resolved:
1. Reset the switch by pressing the
RESET
button on the front panel.
2. Make sure the RS232 connection from the local terminal or PC to
the switch is secure; change the cable if necessary.
3. Unplug the switch from the power source, then plug it back in
again.
4. Contact Allied Telesyn Technical Support for help.
Przeglądanie stron 44
1 2 ... 40 41 42 43 44 45 46 47 48 49 50 ... 67 68

Komentarze do niniejszej Instrukcji

Brak uwag