Chapter 1: Starting a Command Line Management Session
28
What to Configure First
This section has a few suggestions on what to configure when you are
managing the chassis for the first time. The initial management session
must be a local session. For instructions on how to start a local
management session, refer to “Starting a Local Management Session” on
page 20.
Note
Although the management module comes with the default IP
address of 10.0.0.1 and subnet mask of 255.255.252.0, the initial
configuration must be a local session because the module’s Telnet
and SSH servers are initially disabled.
Displaying the
Chassis Modules
After logging on, enter this command:
system show cluster
The command displays the management and media converter modules in
the chassis. You can use this information to verify the modules in the unit.
An example is shown in Figure 4.
Figure 4. Displaying the Chassis Modules
For information about this command, refer to “SYSTEM SHOW
CLUSTER” on page 99.
Chassis Chassis Chassis MAC Master
ID Name Type Address Chassis
------------------------------------------------------------------
0 AT-MCF2000 11:22:33:44:55:55 Yes
Slot ID Module Name Module Type Software Version
------------------------------------------------------------
M AT-MCF2000M v2.0.0
1 AT-MCF2012LC v2.0.0
2 AT-MCF2012LC v2.0.0
Chassis information
Management and media converter module information