AT-S25 Management Software Users Guide
53
3. From the Advanced Configuration window, type 2 to select SNMP
Configuration. The SNMP Configuration menu in Figure 14 is
displayed.
Figure 14 SNMP Configuration Menu
4. Enter or modify the parameters as desired.
To change a value, type its corresponding number and, when
prompted, enter the new value.
To set a switchs SNMP community strings, use the parameters
described below:
1 - GET Community
2 - SET Community
3 - TRAP Community
To specify the IP addresses of up to four management
workstations on your network to receive traps from the switch,
use the selections below:
4 - Trap Receiver 1
5 - Trap Receiver 2
6 - Trap Receiver 3
7 - Trap Receiver 4
5. After making your changes, type S to select Save Configuration
changes.
Changes to the SNMP parameters are immediately activated on
the switch.