Page 160
Allied Telesis
AT-8000GS Command Line Interface Users Guide
Default Configuration
The default speed is 115200 bps.
Command Mode
Line Configuration (console) mode
User Guidelines
This command is available only on the line console.
The configured speed is applied when Autobaud is disabled. This configuration applies only to the current
session.
Example
The following example configures the line baud rate to 9600.
autobaud
The autobaud Line Configuration mode command sets the line for automatic baud rate detection (autobaud). Use
the no form of this command to disable automatic baud rate detection.
Syntax
autobaud
no autobaud
Parameters
This command has no arguments or keywords.
Default Configuration
Autobaud is disabled.
Command Mode
Line Configuration (console) mode
User Guidelines
This command is available only on the line console.
To start communication using Autobaud , press <Enter> twice. This configuration applies only to the current
session.
Example
The following example enables autobaud.
console(config)#
line console
console(config-line)#
speed
9600
console(config)#
line console
console(config-line)#
autobaud